Showing posts with label humeral malposition. Show all posts
Showing posts with label humeral malposition. Show all posts

Wednesday, February 18, 2026

Does component malposition lead to revision of shoulder arthroplasty?

Humeral and glenoid component malposition in patients requiring revision shoulder arthroplasty: a retrospective, cross-sectional study lists instability: 32% (most common in RSA cases (40%). rotator cuff tear: 32% — predominantly in TSA (45%), loosening: 25% (highest in RSA (34%), infection: 11%, periprosthetic fracture: 5%. 

This commercially-funded investigation concluded: "The data from this study suggest that component malposition is frequently present among patients requiring revision arthroplasty." and "Improved component positioning is needed, including the development of more effective intra-operative techniques to ensure proper humeral and glenoid component position to minimize the risk of revision surgery." However, this study did not demonstrate that the rate of malposition was more frequent in revised than in unrevised shoulders. To conclude that malposition causes revision, we need to know how often well-functioning, unrevised shoulders also exceed defined thresholds.

Here are some details: component position was measured on pre-revision radiographs. "Thresholds for Malposition" were based on values found in prior publications.



From the above and the figure below it can be seen that the definition of acceptable component position is quite narrow.


The authors note that using narrower thresholds dramatically increases "malposition" rates. For example, lowering the threshold for the change in humeral center of rotation from >5mm to  >3mm increased the rate of "malpositioned" components from 45% to 58% of TSA cases. It seems likely that there are many unrevised shoulder arthroplasties with a change in humeral center of rotation exceeding the 5mm or the 3mm thresholds.

This is akin to having the distance between field goal uprights being 3 feet (below right) rather than the regulation 18.5 feet (below left).  Narrowing the goal posts does not change the quality of the kicker.




To understand the nature of thresholds, we need scatter plots including both revised and unrevised shoulders that show the relationship between component position and outcomes across the full spectrum of both variables. Such plots would reveal the true clinical significance of positioning variations. These data are not included in this study.

The value of scatter plots is shown by four hypothetical examples illustrating different possible relationships between component positioning and outcomes. Each represents a fundamentally different clinical reality with different implications for the value of precision positioning technology.

Figure 1. Scenario A: Hard Threshold Pattern





This pattern shows a clear inflection point at 5 mm deviation. Below this threshold, outcomes remain excellent with minimal variation. Above it, outcomes deteriorate sharply.  The blue dots represent cases without revision, while red dots indicate cases that required revision surgery.

Figure 2. Scenario B: Soft Threshold Pattern (Gradual Decline)



This pattern demonstrates a linear relationship where each degree of deviation causes proportional outcome deterioration. There is no sharp inflection point. Note the increasing concentration of revisions (red dots) as deviation increases, but many poorly-positioned components still function adequately.

Figure 3. Scenario C: No Clear Relationship (Zone of Indifference)




This pattern shows outcomes scattered across the full range regardless of positioning. The flat trend line suggests that within the measured range, this particular positioning parameter has minimal impact on outcomes. Other factors (soft tissue management, patient selection, surgical technique) dominate. The random distribution of revisions (red dots) across all positioning values supports this interpretation.


Figure 4. Scenario D: Inverted U-Shaped Relationship (Optimal Zone)




This pattern demonstrates that extremes in either direction cause poor outcomes, with an optimal zone in the middle. This could represent parameters like humeral version where both excessive anteversion and retroversion are problematic. The concentration of revisions (red dots) at both extremes supports the concept of an optimal middle zone.

Scatter plots such as these reveal (1) the percentage of "well-positioned" implants failed and (2) the percentage of "malpositioned" implants that function successfully and (3) whether it is likely that deviations caused failure, or whether failures have occurred for other reasons, such as instability from poor soft tissue balancing, poor bone quality, infection, or periprosthetic fracture.

Conclusion

The modes of shoulder arthroplasty failure and revision are well established.

Why do primary anatomic total shoulder arthroplasties fail today? A systematic review and meta-analysis  identified implant loosening (26.1%), particularly of the glenoid component, as the most common cause of contemporary aTSA failure, followed by rotator cuff insufficiency (17.3%), instability (10.4%), and infection (10.2%)


Revision of reverse total shoulder arthroplasty: a scoping review of indications for revision, and revision outcomes, complications, and rerevisions found the primary reasons for revision were dislocation or instability (30%), baseplate complications (25%), infection (23%),  acromial/scapular fractures and humeral component issues (10%).

 Notice that the leading causes of failure — loosening, instability, infection — are not primarily positioning problems. Precision technology addresses none of them.

The critical unanswered question is the dose-response relationship between positioning deviation and clinical outcome - four possible patterns are shown by the hypothetical examples above. 

Each surgeon needs to ask, "are the complications experienced by my patients likely to be addressed by component positioning between tight goal posts or are they more likely to be addressed by better patient selection, better component seating, better soft tissue balancing, better prophylaxis against infection, or different component selection?".


Keeping Cool

Dark Eyed Junco
Matsen Backyard
2020


Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link)
The total shoulder arthroplasty (see this link)
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link)

Shoulder rehabilitation exercises (see this link). 



Monday, February 16, 2026

Humeral and glenoid component malposition in revised shoulder arthroplasty - Part I - what might have been done differently?

The authors of Humeral and glenoid component malposition in patients requiring revision shoulder arthroplasty: a retrospective, cross-sectional study explored 234 cases of revised shoulder arthroplasty and reported "quantitative analysis demonstrated that the majority of glenoid components in these revision cases were malpositioned in both TSA (51%) and RSA (93%) when all measures were considered. Similarly, there was humeral component malposition in 57% of TSA cases, 62% of RSA cases, and 54% of hemiarthroplasty cases when all measures were considered. When asked if there was glenoid component malposition, the independent reviewer considered 17% of glenoid components to be malpositioned in TSA cases and 54% in RSA cases. The investigative institutions reported similar rates. For the humeral side, the independent reviewer felt that 71% of TSA cases, 24% of RSA cases, and 74% of hemiarthroplasty implants were malpositioned in some direction. The investigative institutions reported similar rates."

This article is very thought provoking: it merits two posts. Here's the first.

The authors conclude:  "Improved component positioning is needed, including the development of more effective intra-operative techniques to ensure proper humeral and glenoid component position to minimize the risk of revision surgery." 

The authors' examples of malposition are shown below, providing an opportunity to consider what might have been done differently in each case to avoid the malpostion (see Of successful mammoth hunting and glenoid component failure - modeling causation).

Knowing full well that many of this blog's readers would consider a high-tech approach (e.g.robotics, navigation systems, patient specific instrumentation), here's how we'd try to avoid these malpositions in my practice.

A. Humeral head too high








The "head high" problem may be avoided by assuring that the humeral head is placed just below the berm. 


Note also in both of these cases the diaphysis of the humeral component was too large, causing stem incarceration, preventing full seating of the component. Stem incarceration may be prevented by using a smaller diameter humeral component with impaction grafting, 



using a short stem, or using a stemless component.




B. Insufficient humeral resection



The "long neck" problem may be avoided by full exposure of the anatomic neck for the cut.


C. Too high baseplate


The "Baseplate High" problem may be avoided by making preoperative measurements on a plain preoperative Grashey view. Below left, a line segment equal to half the baseplate diameter is drawn from the inferior glenoid to the articular surface perpendicular to the supraspinatus fossa line. A second line segment is drawn from the inferior glenoid lip to the intersection of the first line segment with the articular surface. This distance can me measured at surgery. This intersection indicates the starting point for the drill.



D. Superior tilt of baseplate. 


The "baseplate looking up" problem may be avoided by making preoperative measurements on a plain preoperative Grashey view. Below left a line (yellow) is drawn from the drill insertion point (see "C" above) parallel to the supraspinatus fossa line. This is the drill trajectory. Below right the angle between the drill trajectory and the superior face of the glenoid is noted and used to define the tilt of the drill for insertion of the baseplate.




Looking forward to your comments!


Northern Flicker
Matsen Backyard
2022



Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link)
The total shoulder arthroplasty (see this link)
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link)
Shoulder rehabilitation exercises (see this link).