Showing posts with label humerus. Show all posts
Showing posts with label humerus. Show all posts

Saturday, March 19, 2016

How important is the humeral head-shaft (neck-shaft) angle in anatomic shoulder arthroplasty?

The rotation of the humeral head does not alter radiographic evaluation of the head-shaft angle.

These authors measured 18 cadaveric humeri. Radiographs were taken with the specimens initially placed in a true anteroposterior position and then subsequently positioned with internal and external rotations of 10°, 20°, and 30°.

For the humerus in the neutral position, the head-shaft angle was 137° ± 4°. With the anatomic specimen positioned with increasing external and internal rotations, there was a maximum difference of only 2° compared with the value observed in the neutral position. The authors concluded that th head-shaft angle did not change significantly with varying degrees of humeral rotation.

Comment: We note that there is substantial variability in the anatomy of the arthritic humerus; the 'anatomic' location of the previously normal articular surface is difficult to determine.

Some surgeons have attached major importance to the humeral head-shaft (neck-shaft) angle in anatomic shoulder arthroplasty. A number of implant systems allow variability in the inclination of the head; however, the effect on the center of rotation of the articular surface seems small.




We use a simpler approach of placing the humeral head at an angle of 45 degrees with the medullary axis of the shaft in all cases, irrespective of the appearance of the preoperative pathoanatomy.



  
The humeral neck cut is always made at 45 degrees with the orthopedic axis, regardless of whether the preoperative films suggest that the neck-shaft angle is

"normal"

or "varus"

or "valgus"
A typical example is shown below.

 


===

Check out the new Shoulder Arthritis Book - click here.



Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including:shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'









Thursday, February 21, 2013

Shoulder fracture dislocation / prosthesis

Here is a case from which we can learn.
A patient sustains a fracture dislocation.


A reduction is attempted in the ER. Substantial force was required.
The post reduction attempt x-ray shows displacement of an anatomical neck fracture that was poorly seen on the prereduction films


Subsequent treatment was with a humeral hemiarthroplasty that is now complicated by tuberosity nonunion, cuff disfunction and pseudoparalysis.

--


Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including:shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.


See from which cities our patients come.


See the countries from which our readers come on this post.

Sunday, December 2, 2012

Management of peri-prosthetic fracture of the humerus with severe bone loss and loosening of the humeral component after total shoulder replacement JBJS B


Management of peri-prosthetic fracture of the humerus with severe bone loss and loosening of the humeral component after total shoulder replacement.

This article emphasizes the difficulty in managing periprosthetic fractures of the humerus. The fractures occurred in older individuals (average age 75, range up to 90 years). The great majority were in women. All but three of the 22 cases were in shoulders with cemented humeral components. 18 patients had severe osteopenia and 4 had mild osteopenia. 17 of the fractures were near the distal tip of the humeral component. While some of the fractures were treated with long stemmed prostheses, others required endoprosthetic replacement of the humerus to the level of the fracture. The authors report a 60% five-year survivorship of these revisions along with complications ranging from instability, component failure, non-union, infection, and nerve palsies.

These authors are to be commended on their valiant attempts to reconstruct these fractures in older individuals with soft bone.

Perhaps the real lesson to be derived from this study is that we need to better understand the factors that might predispose patients to this devastating complication. See our previous posts on the topic. The authors list risk factors as including female gender, revision surgery, press-fit humeral components, rheumatoid arthritis, over-reaming of the humeral canal, proximal humeral deformity or malunion, soft-tissue contracture, aggressive manipulation and osteopenia. It is apparent that any humeral technique that stiffens the upper half of an osteopenic humerus will risk fracture at the tip of the prosthesis. Thus cemented components (as shown in the study) can place the humerus at risk as can press fit components with a tight fit of the prosthetic tip in the diaphysis.



We have sought to minimize the risk of intraoperative and postoperative humeral fractures by avoiding cement (which can create a stress riser at the end of the cement), by avoiding endosteal reaming (which can create a stress riser by notching the inside of the diaphysis), by avoiding a tight cortical fit of the prosthetic stem (which can create a stress riser at the tip of the prosthesis), and by avoiding forcing a too-large prosthesis into smallish bone.

Instead we use intramedullary reamers only to size the canal, stopping as soon as the reamer engages the endosteal surface ('love a first bite') avoiding any notching of the diaphysis as shown on the right below.

We then use impaction grafting (also shown here and here) to build up the inside of the humeral shaft so that a snug fit is achieved without tight contact between the metal stem and the cortex.

Here is a recent post op films of the left shoulder of an 82 year old woman. The humeral component was securely fixed with impaction grafting leaving the tip of the component free of contact with the diaphysis - ergo no stress riser.



Our preferred method for managing periprosthetic fractures is shown here.

--

Use the "Topics" box to the right to find other posts of interest to you.

You may be interested in some of our most visited web pages including:shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.

See the countries from which our readers come on this post.

Sunday, August 7, 2011

Revision surgery for failed shoulder replacement arthroplasty due to humeral fracture - our approach, Part 8

Fracture of the humeral shaft is a recognized cause of shoulder arthroplasty failure. The risk for such a fracture is increased in individuals with poor bone quality or with an increased risk of falling because of poor eyesight, balance problems, confusion, or muscle weakness. The risk is also increased when there has been weakening of the humeral shaft from reaming, as explained in a previous post, or from loosening of the humeral component. Our experience indicates that humeral fracture risk is lessened when endosteal reaming is minimized and when impaction autografting is used to secure the stem in the humeral shaft.


The diagnosis of shaft fracture is revealed by high quality anteroposterior and lateral views that span the entire humerus.  

If the component is not loose, it can be difficult to remove in the presence of a fracture. In this situation, we prefer to leave the prosthesis in place and fix the fracture using a plate placed so that the screws in the proximal fragment pass through the cortical bone either anterior or posterior to the stem of the prosthesis. 

If good fixation in the proximal fragment cannot be achieved with screws, circlage around the plate may be used, but extreme care must be used to avoid circlaging the radial nerve posteriorly and to avoid crushing the bone with excessive tightening of the wires.


If the humeral prosthesis is loose, it may be removed and replaced with a long stem prosthesis fixed with cement or bone graft and supplemented with circlage fixation, again taking care to protect the radial nerve.



In all cases of humeral fracture, we prefer to us autogenous bone graft or cancellous allograft around the fracture site. 





--