Monday, September 1, 2025

One of every eight primary total shoulder replacements required revision by 10 years - a causal analysis - augments/technology assistance

The 2024 Austrialian Orthopaedic Association National Joint Replacement Registry reports, "The cumulative percent revision of primary total conventional shoulder replacements for osteoarthritis is 12.7% at 10 years"  Instability/dislocation was the most common reason for revision (24%) followed by rotator cuff insufficiency (23%) and loosening (17%).



We obviously have room to improve our care of these patients. 
We must ask, "what might have been done differently to minimize this high revision risk for patients having elective shoulder arthroplasty for arthritis?"

These data are important because they are derived from all the shoulder arthroplasties performed for the national population, not from case series from individual surgeons or institutions. As a result they reflect the outcomes for all patients having arthroplasty by all surgeons in Australia. They provide a unique opportunity for Shoulder Arthroplasty Research (SAFR) causal modeling

The registry provides data on non-modifiable patient and shoulder factors (age, sex, ASA score, BMI, preperative shoulder pathoanatomy) and on surgeon-controlled variables (choice of implant, technique of component fixation, use of glenoid augments, size of implants, and technologies such as computer navigation and image derived instrumentation (IDI).

Here are some take-home points based on the remarkable AOA registry.

                                              Non-modifiable risk factors 

Younger age was significantly associated with a higher revision rate (older patients have a hazard ratio (HR) for revision of 0.47). Patients under 55 years of age had the highest revision rate.



Female sex was significantly associated with a higher revision rate (female patients have a 1.27 hazard ratio for revision)



Neither higher ASA score or higher BMI had a statistically significant relationship with revision rate (HRs 1.3 and 0.92, respectively).

Preoperative Walch pathoanatomy did not have significant relationship with revision rate. Importantly, and contrary to the belief of many surgeons, type B2 glenoids were not associated with an increased revision rate (in fact B2 glenoids had the lowest revision rate).


Surgeons can use these data in discussing the revision risk with patients considering elective shoulder arthroplasty for osteoarthritis. 


                                            Surgeon controlled, modifiable risk factors 


Cementless fixation was associated with a significantly higher revision rate than cemented or hybrid fixation (HR 3).



Modular metal backed components have a significantly higher revision rate than all-polyethylene components (HR 3).


Modular metal backed and non-modular metal-backed have significantly higher revision rates that glenoid components with a modified central peg (HR 4 and 2, respectively).



Arthroplasties with augmented glenoid components had a significantly higher risk of revision (HR 1.95).

The use of augments did not lower the rates of different types of failure for anatomic total shoulder performed for osteoarthritis.
The use of augmented glenoid components was associated with a significantly higher risk of revision for type A glenoids and did not lower the risk of revision for type B glenoids.


Arthroplasties in which short humeral stems were used had a lower long term risk of revision.


Arthroplasties in which smaller humeral heads were used were associated with higher rates of revision.


The use of technology assistance (computer navigation, image derived instrumentation (IDI)) was not associated with a decrease in the risk of revision. 


Comment:  The surgeon is the method; the surgeon must ask "what can I do to reduce the risk of revision for my patient?"
(1) The surgeon manages patient selection for surgery and the preoperative discussion with the patient, including the non-modifiable risk factors that increase the risk of revision (young age, female sex, preoperative rotator cuff status) as well as those that appear not to (ASA score, BMI, Walch classification).
(2) The surgeon selects and carries out the procedure in light of the factors that may increase revision risk (metal backed, cementless, and augmented glenoid components) and those that may decrease that risk (larger humeral head and short humeral stems).
(3) Apparently surgeons cannot depend on technology assistance (computer navigation, image derived instrumentation) to reduce the rate of total shoulder revision.


It's about making good choices


Lewis' Woodpecker

Tualatin, OR
2023



Follow on twitter/X: https://x.com/RickMatsen
Follow on facebook: https://www.facebook.com/shoulder.arthritis
Follow on LinkedIn: https://www.linkedin.com/in/rick-matsen-88b1a8133/

Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link).
The total shoulder arthroplasty (see this link).
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link)
Shoulder rehabilitation exercises (see this link).


Friday, August 30, 2024

B3 glenoid in a 73 year old woman, 12 year followup

A 73 year old woman presented with pain and stiffness of the left shoulder. Her radiographs showed glenohumeral arthritis with a retroverted monoconcave (B3) glenoid. Her Simple Shoulder Test indicated that she could not sleep comfortably, reach the small of her back, lift eight pounds, toss, throw, wash back of her opposite shoulder or do her usual work. She had 120 degrees of active elevation with grade 5 strength.



       

After a discussion of the surgical options, she elected an anatomic total shoulder. This was performed without preoperative MRI, CT scan, 3D planning or brachial plexus block. The long head tendon of the biceps was preserved. Conservative glenoid reaming was performed with no attempt to alter glenoid version. A standard (non-augmented) glenoid component was used. A standard length smooth humeral stem was impaction-grafted into the humeral canal.

At 12 years after her arthroplasty at the age of 85, she reported being able to perform 8 of the 12 functions of the Simple Shoulder Test and was pleased with the outcome of her surgery.
Her x-rays at that time show secure fixation of the humeral and glenoid components with bony ingrowth between the fins of the central glenoid peg. Penetration of the anterior glenoid vault by the central peg is seen on the axillary view.


Comment: As pointed out by the authors of Anatomic Total Shoulder Arthroplasty with All-Polyethylene Glenoid Component for Primary Osteoarthritis with Glenoid Deficiencies, this standardized economical approach (minimal reaming, standard, non augmented, glenoid component) is effective across the range of glenoid types:


Humeral centering on the glenoid can be achieved


without change in glenoid version.



Comments welcome at shoulderarthritis@uw.edu

You can support cutting edge shoulder research that is leading to better care for patients with shoulder problems, click on this link

Follow on twitter/X: https://x.com/RickMatsen
Follow on facebook: https://www.facebook.com/shoulder.arthritis
Follow on LinkedIn: https://www.linkedin.com/in/rick-matsen-88b1a8133/

Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link).
The total shoulder arthroplasty (see this link).
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link).
Shoulder rehabilitation exercises (see this link). 


Saturday, March 23, 2024

The value of superior augments in reverse shoulder arthroplasty for shoulders without glenoid deformity



As pointed out the previous blog post (Rocking horse loosening of the baseplate in reverse total shoulder arthroplasty) superiorly augmented baseplates are being used in reverse total shoulder arthroplasty (RSA) with superior gleniod wear, although the clinical benefit to the patient has yet to be demonstrated. 

The authors of Utility of Superior Augments in Reverse Shoulder Arthroplasty (Exactech, Equinoxe GPS) without Significant Glenoid Deformity compared superior augments versus no augment baseplates in RSA for patients with rotator cuff dysfunction and no significant superior glenoid erosion in a multi surgeon retrospective analysis of 145 patients who underwent RSA with  intraoperative navigation (Exactech, Equinoxe GPS). No specific guidelines were applied:  the use of augmented and standard baseplates was determined by the individual surgeon.




Included patients had preoperative superior inclination less than 10 degrees and retroversion less than 15 degrees and had a minimum 20 month followup. Patients selected for augments had higher native superior inclination (5.9 vs. 1.4 degrees). 

At final follow-up, active ROM in all planes was not different between the cohorts. Patient reported outcomes for the augment and non augment groups were not clinically significantly different (i.e. the difference did not exceed the published values for the minimal clinically important difference (MCID). 


The adverse events are shown below


As noted in  Rocking horse loosening of the baseplate in reverse total shoulder arthroplasty, the rate of acromial stress fractures appears to be higher in patients receiving RSA with augmented base plates.

The authors report that they were unable to assess final component positioning or quality of baseplate seating on postoperative imaging given the nature of the multi-center database. 

Achieving good glenoid component seating can be a challenge when using augmented components (see https://shoulderarthritis.blogspot.com/2024/03/what-happens-when-glenoid-version-and.html). 


Comment:  As stated in Influence of Backside Seating Parameters and Augmented Baseplate Components in Virtual Planning for Reverse Shoulder Arthroplasty the use of planning software leads surgeons to chose an augmented glenoid baseplate approximately 85% of the time, even in the presence of minimal deformity. This is in comparison to a less than 20% use of augments when planning software is not used.

The value of augmented components in RSA remain to determined. If the cost of augmented components is greater than that of standard components, the increment in expense would ideally be offset by an increment in the benefit to the patient as demonstrated by comparing the clinical and radiographic outcomes in comparable shoulders. 

You can support cutting edge shoulder research and education that are leading to better care for patients with shoulder problems, click on this link.

Follow on twitter: https://twitter.com/RickMatsen or https://twitter.com/shoulderarth
Follow on facebook: click on this link
Follow on facebook: https://www.facebook.com/frederick.matsen
Follow on LinkedIn: https://www.linkedin.com/in/rick-matsen-88b1a8133/

Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link).
The total shoulder arthroplasty (see this link).
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link).
Shoulder rehabilitation exercises (see this link).


Monday, February 19, 2024

Augmented anatomic glenoid components - are they necessary?

Glenoid retroversion is a common feature of arthritic shoulders. 




In performing anatomic total shoulder arthroplasty, some surgeons accept glenoid retroversion, inserting a standard glenoid component combined with techniques to maintain humeral head centering on the glenoid face while others prefer to change glenoid version (see Glenoid version: acceptors and correctors).

The clinical benefit of changing glenoid version for patients with shoulder arthritis is currently being investigated.

Glenoid components with thicker polyethylene posteriorly (see A, B, C and D below) have been used as a means of changing the version of the glenoid articular surface in anatomic total shoulder arthroplasty.



One of the principal factors in anatomic glenoid component loosening is the rocking horse mechanism in which the component lifts off the bony surface in response to eccentric loading.




2013 The authors of Liftoff resistance of augmented glenoid components during cyclic fatigue loading in the posterior-superior direction used an in vitro model to measure the resistance to anterior glenoid liftoff when the posterior glenoid was eccentrically loaded by translating the humeral head 4 mm in the posterior-superior direction. 



Each of the four augmented designs tested were less stable (i.e. showed greater micro motion with loading) than the standard, non-augmented glenoid component. 




These findings may be related to 
(1) the increased liftoff moment arm (blue line segment) resulting from the greater posterior thickness of the polyethylene as emphasized in 2019 Anatomic Augmented Glenoid Implants for the Management of the B2 Glenoid mentioning "concern for stresses generated in augmented implants", "glenoid augments tested in this study are at higher risk for loss of fixation and glenoid loosening because they were less resistant to liftoff", and "the stepped model showed higher levels of shear stress at both radial mismatch settings at the backside of the implant and in the cement mantle. Thus, while both designs performed similarly, the stepped design had high levels of stress, which indicates a higher risk for loosening, and higher amounts of micromotion in high-risk conditions."




and (2) from difficulty in fitting the bone to a complex component backside (below) in contrast to fitting a convex backed component to a spherically reamed bone surface.


The patient outcomes for the different approaches to the retroverted glenoid need to be compared by well-controlled clinical studies (see 2019 Augmented glenoid implants in anatomic total shoulder arthroplasty: review of available implants and current literature)





2015 Preliminary Results of a Posterior Augmented Glenoid Compared to an all Polyethylene Standard Glenoid in Anatomic Total Shoulder Arthroplasty reported on 24 patients with osteoarthritis and posterior glenoid wear who were treated with aTSA using a PAG with a minimum of two-year follow-up matched to patients treated with an all poly non-augmented pegged glenoid (NAG) for osteoarthritis. Sixty per-cent of PAG shoulders had a radiolucent line with an average radiographic line score of 1.10, and 33.3% of NAG had a radiolucent line with an average radiographic line score of 0.438. One glenoid in the PAG group was radiographically but not clinically loose. In the PAG group, 17/20 humeral heads were centered, and three were anteriorly subluxated; none were posteriorly subluxated. There were no differences in any of the measured postoperative clinical outcomes or any difference in improvement between the two groups.

2019 Early results of augmented anatomic glenoid components compared 37 augmented TSAs matched with 37 control shoulders with unaugmented glenoid components. Both augmented and standard TSAs produced similar improvements in all ROM and PRO measures. Patients with augmented glenoid components were more likely to have type B2 or B3 deformities. At final follow-up, 54% of augmented glenoids showed implant lucencies compared with 46% of control shoulders. The mean Lazarus score was similar between groups (1.5 vs. 1.2). The 16° augmentation demonstrated a significantly higher mean Lazarus score (4.2). Reoperation rates were similar between groups (5% vs. 3%).


2021 Stepped Augmented Glenoid Component in Anatomic Total Shoulder Arthroplasty for B2 and B3 Glenoid Pathology reported the use of a stepped augmented glenoid component to correct glenoid version for Walch B2 and B3 glenoids, comparing the radiographic and clinical outcomes at minimum 2-year follow-up with those achieved with a non-augmented component of the same design in Walch A1 glenoids.



Central peg osteolysis was graded as demonstrated below.


Central peg osteolysis with or without glenoid component shift occurred in 29% of B3 glenoids treated with the augmented glenoid component, 10% of B2 glenoids treated with an augmented component and 5% of A1 glenoids treated with a standard component. The clinical outcomes (Penn Shoulder Scores) and complication rates were not different among the three groups. The authors "would not recommend use of this stepped augmented glenoid component for correction of severe B3 glenoid retroversion that requires excessive anterior glenoid reaming".


2022 Early clinical and radiographic outcomes of anatomic total shoulder arthroplasty with a biconvex posterior augmented glenoid for patients with posterior glenoid erosion: minimum 2-year follow-up reported outcomes for three different amounts of posterior augmentation.





Range of motion and patient reported outcomes improved. Version was corrected. No patient had aseptic loosening. Seventy-nine of 86 patients had a Lazarus score of 0 (no radiolucency seen about peg or keel) at final follow-up.

2022 Mid- to long-term outcomes of augmented and nonaugmented anatomic shoulder arthroplasty in Walch B3 glenoids presented 35 patients having a minimum 6 years followup after aTSA. Sixteen patients had an augmented glenoid component, and 19 patients had a standard glenoid component with partial version correction. Standard or augmented glenoid component use was at the discretion of the operating surgeon, based on the amount of posterior bone loss, joint line medialization, and surgeon training/philosophy in management. Preoperative glenoid retroversion averaged 24 degrees in the standard cohort and 29 degrees in those who received augmented glenoid components. The degree of version correction was not presented. There were no statistically significant differences between those with augmented and standard glenoid components for mean ASES score, ASES pain score, SANE score, percentage patient satisfaction, forward elevation, or external rotation. No patient in either group had undergone revision surgery.


2022 Early outcomes of augmented glenoid components in anatomic total shoulder arthroplasty: a systematic review found 9 studies including 312 shoulders underwent anatomic total shoulder arthroplasty using augmented glenoid implants. At an average of 37.1 months the average clinical outcome scores were improved. Glenoid retroversion was reduced from 21 to 9.5 degrees. Radiolucencies were reported in 35% of shoulders. The 16 degree full-wedge augment led to higher and more severe radiographic lucency, while high peg perforation rates (44%) were observed among 5-mm augment stepped implants. The overall rate of complication was 2.6%. Rate of revision surgery was 1.9%. 


2023 Treatment of Glenoid Wear with the Use of Augmented Glenoid Components in Total Shoulder Arthroplasty: A Scoping Review pointed out that while computer modeling and finite element analysis have suggested that excessive glenoid component retroversion is a risk factor for component loosening, there are no scientific guidelines or consensus on the acceptable degree of component retroversion. The authors emphasize the importance preserving glenoid bone stock and of backside contact for the glenoid component on bone to minimize the risk for glenoid failure. In pointing out the additional cost associated with augmented glenoid components, they categorize three primary designs: full wedge, half wedge, and step-cut. Among these they reported greatest amount of glenoid bone removal in stepped implants 


followed by full- wedge, 




with the lowest amount of bone removal in half-wedge components.





The authors of 2023 Factors associated with functional improvement after posteriorly augmented total shoulder arthroplasty observed that posteriorly augmented glenoid components in anatomic total shoulder arthroplasty (TSA) address posterior glenoid bone loss with inconsistent results. They presented a retrospective review of 50 patients having TSA with a step-type augmented glenoid component at a minimum of 2 years after surgery. 41 had B2 glenoids while 9 had B3 glenoids.




One patient had center-peg osteolysis; 1 patient had glenoid component loosening. Postoperative glenoid component retroversion and residual posterior subluxation relative to the scapular body or glenoid face did not correlate with range of motion or shoulder function. However, humeral head decentering on the glenoid face was moderately associated with lower SANE scores.

2023 Clinical outcome of wedged glenoid reconstruction in anatomic total shoulder arthroplasty for osteoarthritic retroverted glenoid: a minimum 2-year follow-up reviewed 17 patients with a mean preoperative neoglenoid retroversion of 16.7°. The mean improvement was compared to a matched control group demonstrating a comparable magnitude of improvement.







Comment: Glenoid retroversion is common among patients having anatomic total shoulder arthroplasty, yet its importance in determining the outcome of joint replacement is not clear (see Prognostic Value of the Walch Classification for Patients Before and After Shoulder Arthroplasty Performed for Osteoarthritis with An Intact Rotator Cuff). Preoperative CT scans are now commonly used to measure retroversion and to plan its correction, yet the impact of 3D planning on clinical outcomes has not been rigorously determined (see Use of Preoperative CT Scans and Patient-Specific Instrumentation May Not Improve Short-Term Adverse Events After Shoulder Arthroplasty). The articles in the post demonstrate widely varying thresholds for the use of augmented components and little data on the clinical importance of version correction.

As shoulder surgeons we need to keep a keen eye on the strength of clinical evidence supporting the concept that correcting glenoid version and the frequent use of augmented glenoid components is of benefit to our patients. Consider for example the articles below.

2023 Does Glenoid Version and its Correction Impact Outcomes in Anatomic Shoulder Arthroplasty - a Systematic Review recognizes that while there are theoretical advantages to correction of glenoid retroversion in atomic total shoulder arthroplasty, limited information exists on the clinical benefit of correcting glenoid retroversion. The authors reviewed 16 studies evaluating the impact of glenoid retroversion on clinical and radiological outcomes of TSA; nine studies utilized corrective reaming techniques, four studies utilized posteriorly augmented glenoids, and two studies utilized non-corrective reaming techniques. Mean preoperative retroversion ranged from 12.7° to 24°. Eleven studies analyzed the effect of glenoid retroversion on clinical outcomes. The majority of the studies (8/11) did not report any significant association of pre- or postoperative glenoid retroversion on any clinical outcome. Of the three studies that reported significant effects, one study reported a negative association between preoperative glenoid retroversion and PROs, one study reported inferior postoperative abduction in patients with postoperative glenoid retroversion greater than 15 degrees, and one study found an increased clinical failure rate in patients with higher postoperative retroversion. Ten studies reported radiographic results (medial calcar resorption, central peg lucency (CPL) grade, Lazarus lucency grade) at follow-up. Only one study reported a significant effect of pre- and postoperative retroversion greater than 15 degrees on CPL grade. The authors concluded that there is currently insufficient evidence that pre- or postoperative glenoid version influences postoperative outcomes independent of other morphologic factors such as joint line medialization. Given that non-corrective reaming demonstrated favorable postoperative outcomes, and postoperative glenoid version was not significantly and consistently found to impact outcomes, there is inconclusive evidence that correcting glenoid retroversion is routinely required.

Furthermore, Early Radiographic and Clinical Outcomes of Primary Short Stem Anatomic Total Shoulder Arthroplasty with a Peripherally Enhanced Fixation Glenoid: A Multicenter Study "observed glenoid osteolysis in only 5.7% of cases with radiographic follow-up at median 28 months despite wide variation in preoperative glenoid morphology (52% B2 and B3 and only 25% A1)" without using any augmented glenoid components.

All of the above should prompt the search for better clinical evidence to support the currently common use of augmented glenoid components to correct glenoid version in anatomic total shoulder arthroplasty.

You can support cutting edge shoulder research and education that are leading to better care for patients with shoulder problems, click on this link.

Follow on twitter: https://twitter.com/RickMatsen or https://twitter.com/shoulderarth
Follow on facebook: click on this link
Follow on facebook: https://www.facebook.com/frederick.matsen
Follow on LinkedIn: https://www.linkedin.com/in/rick-matsen-88b1a8133/

Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link).
The total shoulder arthroplasty (see this link).
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link).
Shoulder rehabilitation exercises (see this link).