Showing posts with label component. Show all posts
Showing posts with label component. Show all posts

Thursday, February 23, 2012

Glenoid component fixation. Vacuum assist glenoid fixation: does this technique lead to a more durable glenoid component? JSES

JSES October 2011 published an article Vacuum assist glenoid fixation: does this technique lead to a more durable glenoid component? in which suction is applied to the glenoid vault as a means of removing fluid trapped within the glenoid vault and increasing the amount of cement in the glenoid bone for fixation of a glenoid component. They found that using a special device (that is no longer available) to apply suction to the bone the amount of cement in the glenoid was increased and the number of radiolucent zones were diminished. Of note, however, is the observation that even with this method, the authors had 33% radiolucent lines on postoperative x-rays using the Bigliani-Flatow system.

As we have pointed out in a previous post, more cement can generate more heat in the glenoid bone, risking the possibility of thermal damage to the bone, so more cement may not be the goal.

We use a different approach to the removal of fluid from the prepared glenoid bone, employing a carbondioxide spray just before the cement is pressurized.
The consistent result is the absence of radiolucent lines with a minimal amount of cement as shown in the radiograph below.


--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.

Thursday, February 2, 2012

Polyethylene glenoid component for total shoulders - JBJS


In the February Journal of Bone and Joint Surgery, our colleagues Wirth, Rockwood, Iannotti et al have published a Level IV study on 44 shoulders with primary or secondary arthritis having total shoulder arthroplasty with a new design of all polyethylene glenoid component that has flanges on the central peg.  


The authors were careful to disclose consultancy, speakers bureau, patents, royalties, employment, stock/stock option relationships with the company that makes this glenoid prosthesis, DePuy.

These authors have been avid students of the problems patients experience with total shoulders, having reported previously that component loosening accounted for a large percentage of the complications reported for shoulder arthroplasty. Like many others, these authors again identify glenoid component loosening as ‘the foremost cause of medium and long-term failure of shoulder replacements’. 

The authors used the method we published previously for evaluating the x-rays of these shoulders. Initial post-operative x-rays showed 35 of 44 shoulders had a perfect radiolucency grade (80%). At a mean of three years the number of shoulders with a perfect radiolucency grade had diminished to 20 (45%). Three of the shoulders had glenoid osteolysis. The 24 shoulders with glenoid retroversion had poorer glenoid fixation than the 20 shoulders without glenoid retroversion. 

Although there are no direct comparisions to other arthroplasty systems, this glenoid component may have the advantages of using pegs over keels, pegs offset in the superior/inferior and anteroposterior directions, a central peg with flanges to provide initial fixation, and the need for minimal cement.  It is the component we use here at the University of Washington for total shoulder arthroplasty.

It is concern that even though all of these arthroplasties were performed by the individual surgeon inventor who has extensive experience in this procedure, the radiographic results appear to have worsened over the relatively short mean followup period of three years. We look forward to the medium and long term results with this innovative prosthesis.

In this study, seven of the original 51 shoulders (14%) were lost to followup. For the remainder, mean SST scores improved from 3 to 9.  It is of interest that the improvement in shoulder comfort and function in this series of total shoulder arthroplasties, as indicated by the Simple Shoulder Test, are essentially the same as those that have been achieved with the ream and run procedure that avoids the risks associated with glenoid component failure (SST results with ream and run).

Finally, this paper points out that 33,000 of these glenoid components have been installed whereas outcome information is only available (from this and two other papers) on 100 or 0.3% of them. It is worthwhile considering the 'external validity question':  how generalizable is this sample of surgeries carried out by experts in the field to the remaining 29,900 or 99.7% of the arthroplasties for which the results are unavailable?  This comment is not a specific critique of this paper, but rather a reflection on how little we know about the results of shoulder arthroplasty across the country and world, especially since such a large percentage are performed by 'occasional' shoulder arthroplasty surgeons.



--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.

Wednesday, August 17, 2011

Revision surgery for failed shoulder replacement arthroplasty - humeral component revision, Part 13

Removal of a Humeral Implant

In some instances removal of the head of a modular component is sufficient to accomplish the desired revision including gaining access to the glenoid.






Often, however, revision requires removal of the entire humeral component. Extraction of a humeral prosthesis can be straightforward in the case where there is radiolucency in all 7 zones between the humeral endosteum on one hand and the prosthesis and any cement used to fix it on the other.



On the other hand, removal of a humeral prosthesis can be extremely challenging, for example when it has been thoroughly cemented to the bone of an osteopenic humerus or when an ingrowth or textured surface humeral component has been used.  Before embarking on the removal of a cemented humeral component, the difficulty and the necessity of the removal of cement needs to be anticipated.  The need for cement removal is influenced by the presence or absence of infection, the requirement to change prosthesis size and position, and the extent of the cementation.  In the absence of infection and when the cement is secure to the bone, we will often opt to work within the previous cement mantle (for example, using a component with a smaller diameter stem and recementing within the old cement) rather than running the risk of removing it.  The anticipated difficulty and the possibility of fracturing the humeral shaft or tuberosities during the removal are discussed with the patient in detail preoperatively.  The surgical inventory is carefully reviewed to assure that long stem implants of the appropriate diameters and head sizes are available for the subsequent reconstruction.

Our approach to prosthesis removal begins with the removal of soft tissue, bone ingrowth and cement from around the humeral head or, in the case of a modular prosthesis, from around the collar and from around the fins of the prosthesis.


If the prosthesis cannot be removed easily at this point, enough bone in the area of the bicipital groove is cut to allow the positioning of a bone tamp parallel to the shaft with one end beneath the collar or head 





The elbow is flexed to 90 degrees and the arm is stabilized to the thorax while the surgeon strikes the bone tamp so that a longitudinal impact is applied to the proximal prosthesis along the axis of the humeral shaft.  If reasonable impact does not dislodge the prosthesis, a longitudinal humeral osteotomy is started in the bicipital groove.


 When the bone is cut, the osteotome is twisted slightly to open up the endosteal cross section of the humerus.  Impact is applied as before with the bone tamp.  The linear osteotomy is continued sequentially with the osteotome twist each time until the prosthesis can be removed. 



If cement removal is necessary, this can be performed with the usual cement removal tools inserted down from the canal opening at the proximal humerus or through the humeral osteotomy.  In our hands, it seems more safe and effective to monitor the integrity of the bone by extending the incision sufficiently inferiorly so that the bone can be palpated during the cement removal rather than relying on intra operative fluoroscopy.  In any case, burrs and osteotomes tend to cut the often thin and soft bone preferentially to the hard cement; thus the surgeon must be prepared for bone penetration and its possible consequences (nerve damage, additional fracture, leakage of cement).

If a secure cement mantle remains after humeral component removal, the new humeral  component with a smaller diameter can be cemented into the old mantle.

If a cementless reconstruction is desired, the humerus can be reassembled using a long stem prosthesis press fit as far down the distal humerus as possible.


  At this point in the case the medullary canal can be divided into two components – the proximal section that was opened to retrieve the prosthesis and the distal aspect consisting of an intact cylinder.  The fixation of the prosthesis depends on this distal segment, especially in the circumstances where a cementless reconstruction is desired, for example after the debridement of an infected arthroplasty or because of concern regarding an adverse reaction to methylmethacrylate.  In this situation the cylindrical distal humeral segment is reamed with cylindrical reamers until the fit and fill of a cylindrical component stem is optimized. Since the quality of the fit depends on the length of the bone-prosthesis contact, the length of the prosthesis inserted into the cylindrical segment is maximized.  This is accomplished by extending the reaming as distally as possible and by maximizing the length of the prosthetic stem. We often start with a 300 mm stem of the proper diameter, insert it fully in the reamed canal and then measure how much of it needs to be trimmed for the articular surface to be in proper register with the glenoid.  The stem is then cut with a high-speed motorized disk and smoothed of any burrs remaining from the cut.  The prosthesis is then impacted into the distal cylindrical segment paying particular attention to the version.  The open proximal humeral segment is then folded around the prosthesis.  Because the posterior and medial periosteum and muscle attachments have been preserved, the osteotomized bone can be reconstructed by suturing the osteotomy closed using drill holes on either side (the 'bodice' repair).




Circlage can also be used, but care must be taken to protect the radial nerve that can be circlaged in its musculoskeletal groove. 



--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.


Thursday, August 11, 2011

Revision surgery for failed shoulder replacement arthroplasty due to glenoid component failure, Part 11

What if a failed shoulder arthroplasty is associated with instability, that is,  unwanted translation of the humeral head on the glenoid?  Such a shoulder requires a careful  history, examination, and radiographs.  The physical examination of strength in isometric internal rotation with the arm against the abdomen, isometric elevation of the internally rotated arm, and isometric external rotation of the neutrally rotated arm at the side as well as expert shoulder ultrasound can evaluate the integrity of the subscapularis, supraspinatus, and infraspinatus, respectively.  High quality and appropriately oriented anteroposterior and axillary radiographs will reveal the glenohumeral relationship (including the superior/inferior and anteroposterior relationship of the center of the humeral head and the center of the glenoid), the integrity of the tuberosities, the orientation of the glenoid and much about the type and position of the humeral component.  If knowledge of the humeral version is essential, it may be necessary to perform an examination under fluoroscopy, noting the rotational position of the arm that places the humeral neck in greatest profile. 
In terms of treatment options, here are some to consider.


Subscapularis deficiency may not be reconstructable.  If there is good quality muscle and tendon a repair may be possible after a complete release of the medial muscle and tendon.  A hamstring autograft may be useful for extending the tendon length.  


If the glenoid component is in excessive anteversion, its intrinsic balance stability angle does not provide anterior stability due to its misalignment with the net humeral joint reaction force (determined principally by the scapular origin of the scapulohumeral muscles). This etiology of anterior instability is suspected when there is minimal resistance to the anterior load and shift test.  The diagnosis of glenoid component anteversion can be made by examination of a true axillary view of the joint.  The glenoid centerline normally projects out the anterior scapular neck at the centering point.  In the anteverted glenoid, the glenoid centerline projects down the scapular body or behind it.  When anterior instability is associated with glenoid anteversion, reorientation of the prosthetic glenoid centerline is usually indicated.  Because the anterior glenoid lip of a polyethylene component is usually worn by the recurrent instability, the prosthesis often needs to be changed.  Thus, the revision is accomplished either by removal of the prosthetic component and performance of a properly oriented non-prosthetic glenoid arthroplasty or by reinsertion of a glenoid component with its centerline in proper orientation with the scapula. 

If the anterior glenoid bone stock is deficient, an iliac crest bone graft may be secured to the anterior glenoid and then reamed either for a non-prosthetic glenoid arthroplasty or to fit the back of the glenoid prosthesis.


If the glenoid component is in excessive retroversion, its intrinsic balance stability angle does not provide posterior stability.



Clinically, the shoulder will demonstrate diminished resistance to posterior load and shift and instability on cross body adduction.  On the axillary radiograph, the glenoid centerline is seen to project through the bony glenoid more anteriorly than the normal centering point.  As for glenoid anteversion, correction may include re-establishing the normal glenoid centerline and then performing corrective reaming for a non-prosthetic or prosthetic glenoid arthroplasty.



At times it may be necessary to use a posterior bone graft, but it is challenging to obtain secure fixation of the graft to the host glenoid bone.

If there is insufficient glenoid bone for a reconstruction and if an iliac crest autograft cannot be performed because of insufficient quality bone stock to which it can be anchored, a glenoidectomy can be considered as a salvage procedure.  In this procedure the residual glenoid is resected down to the level of the scapular spine.  An appropriately sized humeral head prosthesis is inserted to articulate with the glenoid neck, the scapular spine and the base of the coracoid.


--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.

Wednesday, August 10, 2011

Shoulder arthritis articles from July issue of the JSES - cementing, loosening, venous thromboembolism, resurfacing, revision arthroplasty, hemophilia, arthritis in Korea,

The July issue of JSES has several articles of interest.
The first is a study in cadavers: Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components points out that the more osteoporotic the bone of the glenoid, the more cement can be pressurized into it. While this result is intuitive (porous bone accepts more cement), it has some important implications. As we've show previously, more cement generates more heat as it sets up and more heat can kill bone and dead bone can contribute to loosening of the component. From the figures in this article, it appears that the authors vigorously reamed the bone of the glenoid, perhaps removing much of the firmer cortical bone that lies at the joint surface. We strive to preserve as much of this bone as possible in all cases, but especially in those with soft bone.

A second issue is that these authors state that they tested "primary" stability of the component. But rather than studying the common failure mode: the 'rocking horse', they used direct pull-out, which is a mechanism that is not possible in the living shoulder.

Further, in these 'stability' tests, they found that the components were pulled out of the cement mantle. As the examples below of the many loose glenoids I've retrieved show, this is not the mode of failure in living patients. Instead, glenoid components fail in the clinical situation at the cement-bone interface because the bone around the cement gives way.




Finally, there is a lot to be said about cement technique. The authors state that they used "3rd generation" cementing technique.  Cementing in a cadaver without bleeding is quite different than cementing in a living, bleeding bone. Cement pressurization is easier in cylindrical holes for a pegged component rather than an irregular keel hole. Placing cement on the surface of the bone beneath the prosthesis may offer greater 'initial' stability in cadavers, but this thin layer of cement is subject to fatigue cracking in the living patient.

The bottom line is that even though this is a well-done cadaver study, the clinical application of such cadaver studies must be made cautiously.

---
Next an article entitled, The prevalence of shoulder osteoarthritis in the elderly Korean population: association with risk factors and function, showed that in Korea the risk of OA increased with age and with the co-existence of knee arthritis.

---
Our UK colleagues found that Venous thromboembolic events are rare after shoulder surgery: analysis of a national database. Specifically after total shoulder replacement, the rates of deep venous thrombosis, pulmonary embolism, and death within 90 days were, respectively, 0%, 0.2%, and 0.22%. These rates were not changed by the implementation of thromboembolic prophylaxis. As a result the authors suggest that such prophylaxis may not be necessary.

---
Long-term results and patient satisfaction after shoulder resurfacing provided a minimum of 20 year or until death followup on 61 patients having either hemi resurfacing or total resurfacing procedures.  The satisfaction rate was reported to be high; 7 patients were lost to followup. Twelve of the 41 total resurfacing prostheses showed radiolucent lines but only three had revision surgery for glenoid component loosening.

---
Results of revision from hemiarthroplasty to total shoulder arthroplasty utilizing modular component systems pointed out that it is often possible to revise a painful modular humeral hemiarthroplasty to a total shoulder by removing the humeral head aspect of the humeral component, inserting a glenoid component, and then replacing the humeral head component.

---
Finally, Shoulder arthroplasty in hemophilic arthropathy demonstrated that satisfactory results could be obtained with this complex condition, but that the support of a hematologist was recommended.


--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.

Revision surgery for failed shoulder replacement arthroplasty due to glenoid component failure, Part 10

To continue with our discussion of the management of glenoid component failure, we've observed that attempts to reinsert a new glenoid component are accompanied by a high failure rate due to to the loss of supporting bone (two right hand figures below) in contrast to the situation when the first glenoid component was inserted (two left hand figures below).
Thus when we encounter a substantial glenoid defect, such as that shown below
rather than using a large amount of cement, bone graft, or a special component to fill the defect, we have been pleased with the result from removing all polyethylene, bone cement, and rough bone and then contouring the residual glenoid bone to support a new humeral head component (usually one with a diameter of 56 mm to achieve the maximal contact area). This essentially converts the failed total shoulder to a ream and run. We do not fill the defect with bone graft, finding that the defect fills in itself with time.


--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.


Tuesday, August 9, 2011

Revision surgery for failed shoulder replacement arthroplasty due to glenoid component failure, Part 9

The glenoid component of a total shoulder may fail because of wear (as shown in "B" below)



or because of loosening with radiolucent zones seen in black on x-ray as shown below.


If the glenoid is worn, but securely fixed, it is removed by first cutting the pegs or keel and removing the glenoid component face allowing access to the bone surrounding the fixation so that the remainder of the component and the cement can be dissected from the glenoid bone.
If the glenoid component is loose, it can be easily pried out of the glenoid bone.


We will discuss the management of the glenoid after component removal in the next post.
--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.

Monday, July 25, 2011

Revision surgery for stiff total shoulder replacement arthroplasty - our approach, Part 7

The diagnosis of stiffness is made by the finding of reduced humeroscapular rotational laxity in flexion, cross body adduction, internal and external rotation with the arm at the side and internal and external rotation with the arm in 90 degrees of abduction.  As we saw from a previous post, some cases of stiff shoulder after arthroplasty can be managed with soft tissue releases alone. Often, however, soft tissue releases may be insufficient because of technical problems with the implants.  High quality anteroposterior and axillary radiographs are needed to determine the presence of unwanted bone,



 displaced tuberosities,




 or other ‘hard’ causes of restriction of motion. As shown previously all adhesions in the humeroscapular motion interface are lysed.  A 360-degree release of the subscapularis is performed, freeing it from the coracoid, the coracoid muscles, the axillary nerve and the glenoid lip.  The capsule is released around the periphery of the glenoid – 360 degrees unless there is posterior instability in which case the release is stopped at 190 degrees.

All unwanted bone, such as residual osteophytes between the medial humerus and inferior glenoid, is removed.  If the greater tuberosity is malunited posteriorly, it can block external rotation.  We prefer to avoid tuberosity osteotomy unless it is absolutely necessary because of the difficulties of mobilizing the tuberosity and of obtaining a secure tuberosity union to the shaft after a humeral arthroplasty.  For this reason we prefer to resect prominent tuberosity bone leaving the cuff intact if this is at all possible.

If the joint is overstuffed (the components consume too much of the joint volume) as shown below




the intraarticular prosthetic volume may be reduced by removing or revising the glenoid component, and by reducing the height (thickness) of the humeral component.

Varus positioning of the stem can also result in overstuffing (as shown below) and require component revision.


More often than not, a combination of soft tissue, bony, and component procedures are required to optimize the motion in a stiff arthroplasty.


--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.



Wednesday, June 29, 2011

Failed, Unsatisfactory Shoulder Joint Arthroplasty - glenoid component loosening

As we saw in the June 27 post 59% of patients coming to us for consultation because they were dissatisfied with their total shoulder joint replacement arthroplasty had loose or worn glenoid components.



The concern about glenoid component failure comes from careful followup of patients having shoulder replacements in the past using a variety of older component designs and older techniques. 

Our shoulder fellow Lazarus published a nice paper pointing to the challenges of achieving a perfect glenoid component insertion and the effect of surgeon experience.

Ideal contouring of the bone beneath the glenoid component (as shown below) is essential as pointed out by shoulder fellow Collins.

When the bone is not properly prepared, there is a tendency to pack in a bit of cement to fill in the defect ('putty carpentry'). This is commonly seen in the posterior (back) half of the glenoid as shown below left. However, this wedge of cement is brittle and not fixed to either the component or bone so it can slip out leaving the component unsupported and at risk for loosening (below right).






From a very well done study of 333 total shoulders, here is a graph showing a 50% radiographic survivorship of glenoid components put in 10 years ago.



Loosening seems to be particularly common when the glenoid design consists of a keel that is fixed into the bone of the shoulder blade using a wad of cement as shown below left and in the color photograph of a retrieved glenoid component




Cement cures with an exothermic reaction - this heats the bone to an amount determined by the amount of cement used. Excessive cement can result in thermal death of the bone with loss of fixation as shown by the thermal camera images below.


Removing a loose glenoid component leaves a big hole in the glenoid bone, making subsequent reconstruction difficult.


We have vigorously investigated the causes of failure and ways in which the security of the component can be optimized. We continue to use a modern glenoid component in the majority of our shoulder joint replacements, because it provides predictable recovery of shoulder comfort and function

Time will tell whether the newer design and our modern techniques will improve the long term durability of the glenoid component.


--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.

Monday, June 27, 2011

Failed, Unsatisfactory Shoulder Joint Arthroplasty - stiffness

As noted in the previous post, stiffness is a common feature among unsatisfactory shoulder joint replacements. By stiffness we mean that the shoulder is not capable, even with the help of the other arm, to move through a normal range of motion (see March 29 post). Arthritic shoulders are usually stiff (see April 5 post), so it is not surprising that stiffness may remain a problem even after joint replacement. This is why we are so interested in early post-surgical rehabilitation to maintain the range of motion achieved at surgery (see April 18 and 19 posts). In a technically well-done arthroplasty, range of motion is usually restored and maintained by these rehabilitation exercises.

However there are several surgical principles that are important to re-establishing motion to a stiff, arthritic shoulder. First is that the tight capsule around the joint must be released by sharp dissection as shown in the figure below.


Second is that the bone spurs (osteophytes) be removed to make sure they do not block motion. We refer to the inferior aspect of the joint as Pooh Corner (below left), so that we don't forget to check it and remove any possibility of unwanted contact between the inferior humerus and the glenoid.
We also check for unwanted contact in the posterior aspect of the shoulder that blocks external rotation as shown below.

This can be noted at surgery as the 'open book' phenomenon when the arm is externally rotated - the humeral head is levered away from the glenoid as shown below.
And finally, the surgeon must avoid 'overstuffing' the joint, by inserting such a large humeral head that the soft issues are put under excessive tension (bottom of the figure below) rather than one that puts the soft tissues under normal tension (top of figure below).
Overstuffing can also arise from the insertion of a thick glenoid component - this is one of several issues with metal backed components as shown below right

Finally, overstuffing can arise from varus malposition of the humeral component (the prosthesis is angled toward the socket, rather than being inserted straight) in which case the humerus along with its rotator cuff attachments is pushed away from the glenoid (W), tightening the tissues around the joint.
At surgery, we optimize the shoulder range of motion by assuring that the joint is capable of 40 degrees of external rotation
50% posterior translation
and 60 degrees of internal rotation with the arm out to the side

We refer to these as the 40, 50, 60 rules for achieving ideal soft tissue balance and avoiding an unsatisfactory arthroplasty because of intraoperative causes of stiffness. A good rehabilitation program is still essential to a good result.

If a shoulder stays or becomes stiff after a shoulder arthroplasty and if it does not respond to a good rehabilitation program, revision surgery may be considered to re-release the soft tissue, check to make sure no blocking osteophytes are present, and assure that the humeral head is of the proper size.

--

Use the "Search the Blog" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including: shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery.