Showing posts with label radiographic outcomes. Show all posts
Showing posts with label radiographic outcomes. Show all posts

Sunday, December 25, 2022

What determines the outcome of reverse total shoulder arthroplasty - does geometry matter? Part 1

Since the introduction of the reverse total shoulder arthroplasty (RSA), surgeons have attempted to correlate radiographic measures with clinical outcomes. However, studies such as those listed below did not find clinically significant associations between radiographic measurements and patient-reported outcome measures:

Negligible Correlation between Radiographic Measurements and Clinical Outcomes in Patients Following Primary Reverse Total Shoulder Arthroplasty

Medialized vs. lateralized humeral implant in reverse total shoulder arthroplasty: the comparison of outcomes in pseudoparalysis with massive rotator cuff tear

The lateralization and distalization shoulder angles are important determinants of clinical outcomes in reverse shoulder arthroplasty

A comprehensive evaluation of the association of radiographic measures of lateralization on clinical outcomes following reverse total shoulder arthroplasty


Recently the authors of Influence of Humeral Lengthening on Clinical Outcomes in Reverse Shoulder Arthroplasty assessed the relationship between humeral lengthening and minimal two-year clinical outcomes after RSA, pointing out that while deltoid tensioning from humeral lengthening is theorized to improve the range of motion it might also predispose patients to acromial/scapular spine fractures and neurologic injury. They studied 284 RSAs performed using a single prosthesis design (Exactech/Equinoxe).




They defined humeral lengthening as preoperative to postoperative change in the "subacromial height" (the vertical difference between the most inferolateral aspect of the acromion and the most superior aspect of the greater tuberosity).




The amount of lengthening varied through a broad range:




They found no clinically important differences between shoulders with ≤25 vs. >25 mm of lengthening with respect to ROM measures, outcome scores, or shoulder strength.

The relationship between the postoperative Simple Shoulder Test (left) and improvement in the Simple Shoulder Test (right) as a function of arm lengthening is shown below.




They noted no significant difference in the amount of humeral lengthening between patients with complications and those without complications. Patients with lengthening >25 mm did not have greater rates of acromial fracture or neurologic injury.

The authors of another recent article, Postoperative acromiohumeral interval affects shoulder range of motions following reverse total shoulder arthroplasty sought to analyze various radiographic parameters that may be predictive of clinical outcomes after RSA in 55 patients at a minimum of 2 years followup.
Radiographic parameters included critical shoulder angle, acromial index, acromiohumeral interval, deltoid lever arm, acromial angulation, glenoid version, and acromial height.

They found a very weak negative correlation between the postoperative acromiohumeral interval (see figure below) and forward flexion (r = − 0.270; p = 0.046) and internal rotation (r = 0.275; p = 0.042).



The association between postoperative acromiohumeral interval and external rotation was stronger (r = − 0.421; p = 0.001). A postoperative acromiohumeral interval less than 29 mm had an 86% positive predictive value of obtaining 130° of forward flexion and 45° of external rotation. Excessive distalization reduced forward flexion and external rotation motion of the shoulder.
 
However, essentially radiographic parameters were significantly associated with patient reported outcomes as seen below.





Yet another strudy, Does glenohumeral offset affect clinical outcomes in a lateralized reverse total shoulder arthroplasty? pointed out that there are at least three different RSA geometries:


The authors sought to evaluate how increasing glenohumeral offset affects outcomes after RSA, specifically in a lateralized humerus - medialized glenoid implant model (right hand figure in the illustration above).  

Pre- and postoperative radiographs were analyzed for measurement of glenohumeral offset, defined as the acromial-tuberosity offset (ATO) distance on the anteroposterior radiograph in 130 RSAs.


The mean postoperative absolute ATO was 16 mm, and the mean delta ATO (difference from pre- to postoperatively) was 4.6 mm further lateralized.  When assessing for the effects of lateralization on patient reported outcomes, multivariate analysis failed to reveal a significant effect from the absolute postoperative ATO or the change in ATO on any outcome parameter.

For example, while the Simple Shoulder Test (SST) score improved from 4.0 to 11.0 (p<.001), the SST score was not related to change in ATO: the mean SST was 6.1 for shoulders with a change in ATO <4.6 mm and 6.3 for shoulders with a change in ATO ≥ 4.6 mm. 

The authors concluded that RSA using a lateralized humerus . medialized glenoid implant exhibited excellent clinical outcomes in range of motion and patient recorded outcomes. However, the magnitude of lateralization as measured radiographically by the ATO did not significantly affect these outcomes; patients exhibited universally good outcomes irrespective of the degree of offset.


Comment: Radiographic measures have not been shown to significantly correlated with patient reported clinical outcomes of reverse total shoulder arthroplasty. This finding has three important implications:
(1) currently surgeons do not have robust evidence on which to base their positioning of reverse total shoulder components
(2) the outcomes of reverse total shoulder arthroplasty are largely influenced by factors other than component positioning
(3) clinical research directed a optimizing the clinical outcome of reverse total shoulder arthroplasty needs to include not only data on implant type and positioning, but also the characteristics of the patient (see, for example, One in three patients having shoulder arthroplasty have depression) as well as details of the preoperative condition of the shoulder. 

You can support cutting edge shoulder research that is leading to better care for patients with shoulder problems, click on this link.

To add this blog to your reading list in Google Chrome, click on the reading list icon




Follow on twitter: https://twitter.com/shoulderarth
Follow on facebook: click on this link
Follow on facebook: https://www.facebook.com/frederick.matsen
Follow on LinkedIn: https://www.linkedin.com/in/rick-matsen-88b1a8133/

Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link).
The total shoulder arthroplasty (see this link).
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link).
Shoulder rehabilitation exercises (see this link).



Sunday, June 27, 2021

Reverse total shoulder arthroplasty - adverse radiographic changes

 Radiographic changes around the glenoid component in primary reverse shoulder arthroplasty at mid-term follow-up

These authors analyzed the radiographic changes around the glenoid component and determined the risk factors associated with the presence of these radiographic changes in 105 primary Grammont-style reverse total shoulders with 5 years of radiographic follow-up. 





Standardized digital radiographs obtained immediately postoperatively and at a minimum follow-up time of 5 years were analyzed to determine 

(1) glenoid component position (inclination and height) and 

(2) minor radiographic changes (Sirveaux grade 1 or 2 scapular notching; nondisplaced acromial

fracture; radiolucent lines around 1 or 2 screws; Brooker grade 1a, 1b, or 2 heterotopic calcifications; or single screw rupture), and

(3) major radiographic changes (Sirveaux grade 3 or 4 scapular notching; radiolucent lines around 3 screws or central peg; Brooker grade 1c or 3 heterotopic calcifications; prosthetic dislocation; loosening or migration; or disassembly).


Major radiologic changes were identified in 14.3% of the cases. Bivariate analysis showed that more changes were associated with the arthroplasties implanted in the first years of the study.


Multivariate analysis revealed an increased risk of severe scapular notching mainly associated with superior tilt of the baseplate and a high glenosphere position.


They also noted an increased risk of loosening with superior tilt.



Superior tilt of baseplate


Superior position of glenosphere



Comment: This is an informative case series. It demonstrates some of the challenges associated with designs of reverse total shoulder in which a glenoid hemisphere is placed directly on the glenoid bone. This results in medialization of the proximal humerus with the associated risk of scapular notching. This risk is further increased by superior positioning of the glenosphere and superior inclination of the baseplate.

These issues can be addressed by positioning the glenosphere flush with the lower edge of the glenoid bone, by avoiding superior inclination and by using an offset glenosphere, which can be accomplished with a bone graft as shown in yellow below right
or by using a glenosphere offset by a neck as shown below.


Our technique for reverse total shoulder arthroplasty is shown in this link.



How you can support research in shoulder surgery Click on this link.

Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The total shoulder arthroplasty (see this link).
The ream and run technique is shown in this link.
The cuff tear arthropathy arthroplasty (see this link).

The smooth and move procedure for irreparable rotator cuff tears (see this link).
Shoulder rehabilitation exercises (see this link).


Sunday, October 28, 2018

Total shoulder arthroplasty - what matters?

Radiographic comparison of finned, cementless central pegged glenoid component and conventional cemented pegged glenoid component in total shoulder arthroplasty: a prospective randomized study

These authors prospectively compare radiographic lucency between a finned, cementless central pegged glenoid component


and a conventional cemented pegged glenoid component 


on immediate postoperative and minimum 2-year follow-up radiographs.

Fifty-four patients undergoing total shoulder arthroplasty were prospectively randomized to receive one of the two glenoid components. 

Patients who had undergone revision surgery or had died before evaluation were excluded. 

Fifty patients met inclusion criteria; 42 were available for followup with the original glenoid implant in place. The mean follow-up duration was 35 months (24-64 months).

At a mean of 35 months after surgery, there were no significant differences in glenoid radiolucency between the two components.  

Comment:  This is an important randomized control trial with short term radiographic followup without clinical outcome data.

It is recognized that glenoid component failure is often delayed, usually appearing 10 years after surgery. A recent study of 333 patients, Results of a convex-back cemented keeled glenoid component in primary osteoarthritis: multicenter study with a follow-up greater than 5 years, found radiologic loosening of 0.3% at 5 years and 48.5% at 10 years.

It is hoped that these authors will be able to follow this cohort for another eight years to assess the radiographic and clinical status of the shoulders. To that point it is of interest that some of the shoulders in this series showed early glenoid loosening

while others showed superior displacement of the humeral component relative to the glenoid - a situation known to risk subsequent rocking horse loosening of the glenoid component.


It is of interest that the great majority of these cases were done for glenoid type A pathology:
79% type A 21% type B
This distribution of pathoanatomy is different from that in most reports. For example in the above referenced study of 333 shoulders, there were
54% type A, 42% type B, 4% other

In type A pathoanatomy, shown below, the humerus is centered in the glenoid.
 Many believe that type B glenoids (shown below) are at higher risk for glenoid component failure. 

It seems likely that these authors treated many of their type B glenoids with another type of arthroplasty.

Seven complications (13%) occurred in the 54 patients initially enrolled in the study:
one intraoperative proximal humerus metaphyseal fracture
one postoperative traumatic rupture of the subscapularis tendon
one intraoperative nondisplaced greater tuberosity fracture 
two glenohumeral dislocations (1 anterior and 1 posterior) 
one postoperative infection 
one small anterior glenoid fracture that occurred during glenoid reaming


=====
We have a new set of shoulder youtubes about the shoulder, check them out at this link.

Be sure to visit "Ream and Run - the state of the art"  regarding this radically conservative approach to shoulder arthritis at this link and this link

Use the "Search" box to the right to find other topics of interest to you.


You may be interested in some of our most visited web pages   arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'

Sunday, January 29, 2017

Shoulder hemiarthroplasty

Risk factors for glenoid erosion in patients with shoulder hemiarthroplasty: an analysis of 118 cases

These authors reviewed radiographs of 118 hemiarthroplasties in 113 patients with a mean follow-up of 31 months (range, 5-86 months).

Attempts in quantifying glenoid erosion by determining several parameters and their change over the postoperative period were made (beta angle, critical shoulder angle, medialization of prosthetic head).


However, the authors concluded that none of them was consistent in quantifying erosion. While the authors obtained preoperative CT scans on almost all shoulders, they did not attempt to use CT scans to evaluate erosion at followup.

Therefore, they graded glenoid erosion on plain films using a system described in 2007 (see this link) as (grade 1) none; (grade 2) mild (erosion into the subchondral bone); (grade 3) moderate (medialization of the glenoid subchondral bone with hemispheric conforming deformation of the glenoid); or (grade 4) severe (complete hemispheric deformation of the glenoid with superior bone loss to the base of the coracoid base).

In this series, erosion after hemiarthroplasty was associated with glenoid cysts, loss of glenoid cartilage, rotator cuff degeneration, female sex, rheumatoid arthritis, and implantation of the prosthetic head in a valgus position. The relationship of radiographic estimates of erosion to the clinical outcomes in these patients is not reported.


Comment: These factors are very similar to those affecting clinical outcomes of shoulder hemiarthroplasty as reported thirteen years ago in the article "Preoperative Factors Associated with Improvements in Shoulder Function After Humeral Hemiarthroplasty", the abstract of which is reproduced below;

Background: The relationship between the characteristics of the shoulder that can be determined before humeral hemiarthroplasty and the functional improvement after surgery is not known. The goal of this study was to test the hypothesis that the functional outcome of this procedure correlated significantly with factors that are identifiable preoperatively.

Methods: The study group included seventy-one shoulders in sixty-eight patients undergoing hemiarthroplasty, performed by the same surgeon, for diagnoses other than acute fracture. The mean age of the patients was sixty-one years (range, thirty to eighty-three years). The results were characterized in terms of the change in self-assessed shoulder function and general health status at an average of forty-nine months (range, twenty-four to 142 months) after surgery.

Results: The preoperative absence of erosion of the glenoid was associated with greater improvement in shoulder function and level of comfort after hemiarthroplasty (p < 0.001). Shoulders that had not had previous surgery had greater functional improvement than did those that had previous surgery (p = 0.012). Shoulders with an intact rotator cuff showed significantly (p < 0.5) greater improvement in the ability to lift weight above shoulder level after hemiarthroplasty (p <0.5). With regard to diagnoses, shoulders with rheumatoid arthritis, capsulorrhaphy arthropathy, and cuff tear arthropathy had the least functional improvement, whereas those with osteonecrosis (p = 0.0004) and with primary (p = 0.02) and secondary degenerative joint disease (p = 0.03) had the greatest improvement. Patient age and gender did not significantly affect the outcome.

Conclusions: These results suggest that the functional improvement following humeral hemiarthroplasty is related to factors that are identifiable before surgery. These data may be of benefit in preoperative discussions with patients who have a shoulder disorder and are considering treatment with hemiarthroplasty.

===



To see the topics covered in this Blog, click here

Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including:shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'