Thursday, December 6, 2018

Delta XTEND reverse total shoulder - how to best position it.

Geometric modification of the humeral position after total reverse shoulder arthroplasty: what is the optimal lowering of the humerus?

The Delta XTEND is a Grammont - style reverse total shoulder arthroplasty. It achieves stability by non-physiologic distal and medial displacement of the humerus relative to the scapula as shown below.



These authors sought to determine the relationship between lowering and medialization of the humerus and the short-term functional results.

In 70 patients the mean humeral lowering was 25.4 mm (range, 6-38 mm), and the mean medialization was 9.2 mm (range, 0-20 mm). 

 At 1 year of follow-up, scapular notching was found in 20 shoulders (29%): type I notching was observed in 18 and type II notching in 2. At 2 years of follow-up, only 54 patients were available for a radiographic review. Scapular notching was found in 25 patients (46%): type I notching was observed in 15, type II notching in 7, and type III notching in 3. No scapular spine or acromion fractures occurred.

They divided the lowering values the cohort into terciles below 24 above 28 mm and in between.
Active anterior elevation, which was somewhat greater in the group with >28 mm of lowering in comparison to the group with less than 24 mm of lowering. Neither the Constant-Murley score nor the pain score were influenced by the humeral lowering.

The rate of scapular notching was inconsistently related to the degree of lowering. 







Comment: The high rate of scapular notching with this type of prosthesis (46%) is noted (example shown below).


Our preference is for a design that achieves stability with East - West tensioning, enabling a more anatomic reconstruction without the need for distalization, which may jeopardize the acromion and the brachial plexus. 

The point is that the positioning of the implant depends a lot on the implant design.
=====
We have a new set of shoulder youtubes about the shoulder, check them out at this link.

Be sure to visit "Ream and Run - the state of the art" regarding this radically conservative approach to shoulder arthritis at this link and this link

Use the "Search" box to the right to find other topics of interest to you.


You may be interested in some of our most visited web pages arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'

Saturday, May 5, 2018

How important is humeral component positioning in total shoulder arthroplasty?

Does prosthetic humeral articular surface positioning associate with outcome after total shoulder arthroplasty?

These authors sought to determine the effect of humeral articular component positioning on changes in patient-reported outcomes after anatomic total shoulder arthroplasty in 95 patients from one of two high-volume referral centers with a mean followup of 4.3 years. The study included patients with (1) a preoperative and postoperative radiograph demonstrating a perfect or nearly perfect profile of the humerus and implant and (2) clinical scores preoperatively and at greater than 2 years postoperatively. 

The distance and direction from the ideal center of rotation to the reconstructed center of rotation was measured. 

The COR shift was >2 mm in 62% of patients and >4 mm 15%. The Simple Shoulder Test scores improved from 3.4 to 9.8. 

On multivariate analysis, there were no significant associations between any change in measured prosthetic radiographic parameters and changes in the visual analog scale, Simple Shoulder Test, or ASES scores (P > .05).

Comment: What this study actually shows is that the expert surgeons from these high volume centers were able to consistently place the humeral component in a functional position. This study must not be interpreted as showing that the positioning of the humeral component is unimportant. In fact, high positioning of the humeral component is an important cause of 'rocking horse' loosening of the humeral component as shown below


High positioning often arises from the use of a humeral body that is too large to completely seat in the humeral canal.

An interesting aspect of this study is that while 37 of the glenoids in this study were type B, the good results were achieved without the use of a posteriorly augmented glenoid component.
====