Thursday, September 17, 2020

Metal back, uncemented glenoid components in total shoulder arthroplasty?

 Cemented vs. uncemented glenoid fixation in total shoulder arthroplasty for osteoarthritis: a New Zealand Joint Registry study

These authors used the New Zealand Joint Registry (NZJR) data from from January 2000 to December 2017 to compare all-cause revision rates and functional scores for total shoulder arthroplasty (TSA) and investigated the trends of glenoid fixation used in New Zealand.


A total of 2613 TSAs were performed for OA during the study period, representing 85.0% of all TSAs in New Zealand. 69.6% of glenoids were cemented and 30.4% uncemented. The most common uncemented MB glenoids were the SMR 86.6% (LimaCorporate) and the Bigliani-Flatow.





 The most common cemented glenoid components were Global (DePuy) 49.8% and Aequalis.



 



The revision rate for TSA with uncemented glenoids was significantly higher at 2.03 compared with cemented at 0.41 per 100 component-years. 


The hazard ratio was 5.0 for revision of uncemented glenoids. 


The most common mode of failure was glenoid loosening in cemented glenoids (44.4%), and component failure in uncemented (34.8%). 


Revision for rotator cuff, deep infection, and instability were comparable between

groups. 


When excluding SMR L2, uncemented MB glenoid all-cause revision rates remained significantly higher than cemented (1.42 vs. 0.41 per 100 component-years, P < .001). SMR L1 uncemented MB glenoids had a higher revision rate than the non-SMR uncemented glenoids (1.61 vs. 0.18 per 100 component-years. 

Uncemented glenoid use peaked in New Zealand in 2011 at 46.7% of TSAs but declined to 20.1% in 2017.


Comment: These data reinforce prior studies showing the superior survivorship for cemented cross linked all-polyethylene glenoids (see data below from the Australian Orthopaedic Association). 





Our approach to total shoulder arthroplasty is shown in this link.


To subscribe to this blog, enter your email in the box to your right that looks like the below



===
How you can support research in shoulder surgery Click on this link.

We have a new set of shoulder youtubes about the shoulder, check them out at this link.

Be sure to visit "Ream and Run - the state of the art" regarding this radically conservative approach to shoulder arthritis at this link and this link

Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages  arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'

Sunday, June 28, 2020

Total shoulder arthroplasty - uncemented glenoids have five times the revision rate

Cemented vs. uncemented glenoid fixation in total shoulder arthroplasty for osteoarthritis: a New Zealand Joint Registry study

These authors note that uncemented metal-backed glenoid components were introduced in an attempt to avoid glenoid loosening. They used the New Zealand Joint Registry data from January 2000 to December 2017 to compare all-cause revision rates and functional scores for TSA.

A total of 2613 TSAs were performed for OA during the study period, representing 85.0% of all TSAs in New Zealand.

69.6% of glenoids were cemented and 30.4% uncemented. 

The most common uncemented metal backed glenoid was SMR 86.6% (LimaCorporate).


The most common cemented glenoid was Global (DePuy) 49.8%.



The revision rate for TSA with uncemented glenoids was significantly higher at 2.03 compared with cemented at 0.41 per 100 component-years (P < .001).

The hazard ratio was 5.0 for revision of uncemented glenoids.

The most common mode of failure was glenoid loosening in cemented glenoids (44.4%), and component failure in uncemented (34.8%).

When excluding SMR L2, uncemented MB glenoid all-cause revision rates remained significantly higher than cemented (1.42 vs. 0.41 per 100 component-years, P < .001).

SMR L1 uncemented MB glenoids had a higher revision rate than the non-SMR uncemented glenoids (1.61 vs. 0.18 per 100 component-years, P . .009).

Uncemented glenoid use peaked in New Zealand in 2011 at 46.7% of TSAs but declined to 20.1% in 2017.

Comment: It is difficult to understand the passion for "cementless" glenoid fixation when the 10 year revision rate for cemented cross-linked glenoid components reported by the Australian Orthopaedic Association is 3% (see below)









Cemented fixation of an all-poly glenoid component with a fluted central peg has shown great clinical utility in a large international study (see this link).

Here's a related article Clinical and radiographic outcomes of an all-polyethylene fluted central peg glenoid component, implanted utilizing an off-label, uncemented technique, at a minimum 5-year

===

To see a YouTube on how we do total shoulder arthroplasty with an emphasis on glenoid preparation, click on this link.

===


To see our new series of youtube videos on important shoulder surgeries and how they are done, click here.

Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages  arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'




Saturday, March 1, 2014

Cementless reverse total shoulder

Clinical and radiographic results of cementless reverse total shoulder arthroplasty: a comparative study with 2 to 5 years of follow-up.

The authors report a retrospective review of  patients having reverse total shoulder arthroplasty for a diagnosis of cuff tear arthropathy or severe rotator cuff deficiency. Of these, 37 patients had cemented RTSA and 64 patients had cementless RTSA. The cemented RTSAs were implanted between 2005 and 2007, and the uncemented RTSAs were implanted between 2007 and 2008.

There were no significant differences in clinical or radiographic outcomes between the two groups of patients. There was one revision for prosthetic instability  in the cemented group and three such cases in two patients in the cemented group.

Comment: This series represents the results by a surgeon with extensive experience with reverse total shoulders in patients with the optimal diagnoses: cuff tears and cuff tear arthropathy. Results are not presented for patients having reverse total shoulders for failed anatomic arthroplasty or fractures.

The authors observed stress shielding exclusively in the cement less stems, noting that stress shielding has been noted to be inversely proportional to the diameter of the stem: increased stiffness of the larger diameter press-fit implants leads to more stress shielding and increased proximal bone resorption around the implant.

In order to achieve fixation without cement, the average stem diameters were greater in the uncemented group.

This observation suggests that care needs to be exerted when inserting press-fit humeral stems in fragile bone because of the risk of fracture at surgery. Many patients having reverse total shoulders have poor humeral bone quality. Special approaches may be needed to avoid the risk of fracture at and after surgery.

===
Consultation for those who live a distance away from Seattle.

Check out the new Shoulder Arthritis Book - click here.

Click here to see the new Rotator Cuff Book

To see the topics covered in this Blog, click here

Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including:shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'


Monday, February 17, 2014

Uncemented metal backed glenoids - high revision rate

Effect of glenoid cementation on total shoulder arthroplasty for degenerative arthritis of the shoulder: a review of the New Zealand National Joint Registry.

The first sentence of this article is worthy of our attention, "Despite the lack of literature showing improved results compared with cemented designs, uncemented glenoid components are still commonly used in total shoulder arthroplasty".

These authors used the New Zealand National Joint Registry data to compare the outcomes of uncemented and cemented glenoids in total shoulder arthroplasty for degenerative arthritis.

They retrieved data on 1596 patients, with a mean follow-up 3.5 years (range 2-10.7 years). 1065 had a cemented glenoid and 531 an uncemented component. The median follow-up time was 3.5 years (range, 2-10.7 years).There were no significant differences in any preoperative factors between the patients receiving cemented and uncemented glenoids. The revision rate for uncemented glenoids was 4.4 times higher than for cemented glenoids (1.92 vs 0.44 revisions per 100 component-years, P < .001).

Age <55 years was an independent risk factor for revision (P < .001). 

The uncemented prosthesis used in most of these cases has now been taken off the market. All of the cementless revisions were in shoulders receiving this component.



The most common reasons for revision are shown below.


These data are very interesting, in that (1) polyethylene failure and liner dissociation was the most common reason for revision in the uncemented metal backed glenoids, (2) rotator cuff failure was a common mode of failure, and (3) a high percentage of failures were related to posterior instability. It would be of great interest to know the glenoid pathology in these cases of posterior instability. 

The glenoid component remains the weakest link in total shoulder arthroplasty.
===
To learn more about shoulder arthritis and what can be done about it, see the Shoulder Arthritis Book.

To learn more about the rotator cuff, see the Rotator Cuff Book

Consultation for those who live a distance away from Seattle.

To see the topics covered in this Blog, click here

Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including:shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, androtator cuff surgery as well as the 'ream and run essentials'

See from which cities our patients come.

See the countries from which our readers come on this post.

Thursday, November 28, 2013

Lack of demonstrated advantage of cementless metal backed glenoid components


Effect of glenoid cementation on total shoulder arthroplasty for degenerative arthritis of the shoulder.

A prior report based on the Australian Joint registry showed poorer results with a metal-backed glenoid with a high incidence of breakage and dissociation.

These authors used the New Zealand National Joint Registry compare the outcomes of uncemented and cemented glenoids in TSA performed for degenerative arthritis in 1596 patients followed for a mean of 3.5 years (range 2-10.7 years).  1065 had a cemented glenoid. This study does not identify the reasons surgeons decided to use one type of fixation or other.

There were no significant differences in any preoperative factors between the 2 groups. The revision rate for uncemented glenoids was 4.4 times higher than for cemented glenoids (1.92 vs 0.44 revisions per 100 component-years, P < .001).

Noting that some patients had more than one reason for failure, the most common reasons for failure were different between the metal backed and the cemented poly components.


We have previously posted comments on why this might be.

It is of interest that the traditional '2 years followup' does not reveal the actual problem with glenoid component failure, which continues with time. Note that the apparent plateau in the survivorship curve for metal backed uncemented is probably related to the lack of longer term followup for these components.



The authors also observed that age <55 years was an independent risk factor for revision (P < .001). For both uncemented and cemented components, the failure rate for patients <55 was over twice that for individuals >55 years.

The effect of age and of component type were independent of each other.

The results do not provide evidence in support of the use of metal backed components (a finding similar to prior studies that have been posted previously).

The increased revision rate for younger patients is also a consistent finding and suggests that in some young patients a glenohumeral arthroplasty without a glenoid prosthesis may be considered.

===
Consultation for those who live a distance away from Seattle.

**Check out the new (under construction) Shoulder Arthritis Book - click here.**

To see the topics covered in this Blog, click here

Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages including:shoulder arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'

See from which cities our patients come.

See the countries from which our readers come on this post.


Monday, December 31, 2012

Uncemented reverse total shoulder

Radiographic results of fully uncemented trabecular metal reverse shoulder system at 1 and 2 years’ follow-up

This is radiographic followup of 98 patients undergoing uncemented reverse total shoulders. 48 had rotator cuff arthropathy, 24 had massive rotator cuff tear, 7 had rheumatoid arthritis with rotator cuff tear, 7 had failed hemiarthroplasty due to rotator cuff arthropathy, 4 had failed hemiarthroplasty due to fracture, 3 had osteoarthritis with rotator cuff tear, 3 had failed TSA due to rotator cuff tear, and 3 had failed proximal humerus open reduction– internal fixation. 

Of the 98 shoulders with followup of one year, 6% of the stems had lucent lines - these were less than 2mm. 21% of these shoulders had type 1 scapular notching, and 2% had type 2 notching. 

Of the 40 shoulders with followup of 2 years, 10% of humeral stem components had lucent lines - these were less than 2 mm. 34.2% of the scapulae had type 1 notching, 5.3% had type 2 notching, and 2.6% had type 3 notching. No stems had lucency in more than 1 zone or lucency ≥ 2 mm; 9.2% had subsidence of 2 mm or less. No glenoid components had any lucency around the baseplate or screws.

None of the patients were know to have required revision or any additional surgeries during the follow-up period.

While clinical out comes for these patients are not presented, these radiographic results are encouraging. As we pointed out in a previous post, obtaining stability of the humeral component is a greater challenge in reverse than in anatomic shoulder arthroplasty. In this series a press fit technique was used for humeral fixation. In using this method, the surgeon must be careful to avoid fracture while attempting to achieve secure fixation, especially in light of the frail bone often encountered in the older patients requiring reverse total shoulder arthroplasty.


--