To Patch or Not To Patch in Cuff Repairs

The Summary

A patch may make the cuff-repaired shoulder tendon look better on MRI. However, robust evidence is lacking that patient-reported outcomes are clinically significantly better for patients having cuff repairs with a patch than those with unpatched repairs.

Rotator cuff repair is one of the most common operations in orthopaedics. However, the repaired tendon does not always stay attached to the bone: on MRI, roughly a quarter of repairs show a retear within a year or two. This is especially the case for the most common type of cuff pathology: the degenerative tear, the repair of which is at risk for failure because of the limited quantity and quality of the muscle, tendon, bone unit required for cuff function.

Biologic patches are commonly used with the goal of improving the outcomes of cuff repair. For example, the bovine bioinductive patch (Regeneten) is a thin sheet of purified collagen from cow tendon. The surgeon sutures it over the repaired tendon, and the body is meant to grow new tendon-like tissue into it. In August 2025 the American Academy of Orthopaedic Surgeons gave the patch its highest grade of endorsement, a “strong” recommendation, saying it can lead to lower retear rates and better patient-reported outcomes.

The first half of that statement is supported. The second half appears to lack solid evidence.

Two trials, two different questions

The AAOS recommendation rests on two randomized trials of the same implant. The larger one, from Spain and supported in part by the manufacturer, randomized 124 patients with fully repairable tears 1 to 4 cm across (on average about 2 cm) to a standard repair with or without the patch. At two years, 12% of patched repairs had retorn on MRI, compared with 35% of unpatched ones. But the patients’ ratings of pain and function were the same in both groups at every visit. The authors titled their two-year report “a lower retear rate but similar outcomes.”

The smaller trial, of 60 patients at one center, asked a different question: could the patch replace a repair altogether in small tears (2.5 cm or less, with the rotator cable intact)? Those patients did score better: 8 points higher on the ASES shoulder score, but this difference is not clinically significant (less than the minimal clinically important difference).

In other words, neither trial showed an important difference in patient comfort and function.

Why a healed tendon does not necessarily lead to a better shoulder

A meta-analysis of 20 randomized trials of biologic augmentation helps explain the paradox. Shoulders whose repairs stayed intact scored better than those that retore, by about 14 points on the ASES and 10 on the Constant. But about three of four repairs heal anyway without augmentation, so augmentation prevented a retear in only about 12 of every 100 shoulders. If augmentation were applied to all cuff repairs, the average gain would be 1 to 2 points per patient on the 100-point ASES and Constant shoulder scores, far too small a benefit for the average patient to notice.

Other studies suggest that a retear has less impact on patient comfort and function than the appearance on MRI might imply. Pooled data from more than 3,000 repairs found that patients with retorn tendons scored only 6 to 7 points lower than those whose tendons healed, and most were satisfied.

The cost

The patch adds time and expense to surgery: estimates range from $5,000 to $10,000 per case. Non industry sponsored studies have also reported a downside that the AAOS guideline does not mention: stiffness. In one matched comparison, 9% of patched shoulders needed a second operation for inflammation and stiffness, compared with none of the unpatched ones. In another, six of 32 patched shoulders and none of 32 controls were reoperated for stiffness.

“What’s New in Sports Medicine” and “What’s New in Shoulder and Elbow Surgery”

The 2026 “What’s New” reviews in the Journal of Bone & Joint Surgery report the same pattern for other add-ons to cuff repair. Injected skin cells, drilling the bone and an osteoporosis drug each improved the tendon’s appearance on MRI without a clinically meaningful change in patient reported outcomes. Neither review mentions patches.

Readers of patch reports should be wary of conclusions from reviews. A 2026 study found that 13 of 16 published reviews of patch augmentation contained “spin” in their abstracts, presenting results more favorably than the data supported.

What patients and surgeons can ask

None of this means the patch never helps. For massive tears or poor-quality tendon, where retears are most likely, patches may prove worthwhile over the long haul, but most trials have followed patients for only one to two years. Until a trial shows that patients have better long-term comfort and function, the burden of proof falls on the proponents of the device. We can reasonably ask: Will it make the shoulder feel and work better? What will it add to the cost? What is the risk that it will make the shoulder stiff?


The details

Many shoulder surgeons are using bioinductive patches in rotator cuff repair. The evidence offered for patches is based mostly on MRI images, histology and retear rates. Robust evidence of a clinically significant improvement in patient comfort and function with their use is lacking. Recent JBJS “What’s New” articles review a series of randomized trials in which adjuncts to cuff repair improved healing on MRI without a clinically significant improvement in patient-reported outcomes [1,2]. One states that optimizing the biological environment after cuff repair “remains a challenge” [2]. Neither article mentions patch augmentation.

What the 2026 “What’s New” articles report

Both updates review a year of randomized trials in rotator cuff surgery [1,2]. The cuff trials they chose share a pattern: the adjunct improves the tendon on MRI; the patient outcomes are not different.

•    Autologous dermal fibroblast injection. Retear at 6 months fell from 24.3% to 5.6%, with no difference in ASES, Constant or SST scores [3].

•    Bone marrow stimulation. Incomplete healing at 2 years fell from 54.7% to 33.9%, but ASES scores were 89.2 and 87.8 (p = 0.498) [4].

•    Zoledronic acid. Retear at 6 months fell from 35% to 15%, with what the authors of the update called “modest” clinical improvement [1,5].

If a lower retear rate reliably meant a better shoulder, at least one of these trials should have shown a difference in patient-reported outcome at the minimal clinically important difference (MCID). None did.

What the pooled randomized trials show

Our recent meta-analysis of 20 Level I randomized trials (1,327 shoulders) of biologic augmentation confirms this pattern [6]. Augmentation lowered the retear rate from 26.7% to 14.8% (risk ratio 0.62). For patch augmentation alone (153 shoulders), the retear rate was 17.6%, a risk ratio of 0.55 [6]. Yet no patient-reported outcome improved by the MCID. The pooled differences were 0.9 points for the ASES and 2.2 points for the Constant score. In the patch subgroup the Constant score was only 3.9 points higher, and the ASES was not different [6].

Why does a healed tendon not translate into a better result? Intact repairs did score 14.3 ASES points and 10.5 Constant points higher than retorn repairs [6]. But because about 73% of unaugmented repairs heal, augmentation prevents a retear in only about 12 of every 100 shoulders. Spread across all the patients who receive it, the expected gain in outcome score per patient is only 1.3 to 1.7 points [6]. 

Other meta-analyses suggest that even this gap may overstate what a retear costs the patient. Across 43 study arms (3,350 repairs, 25% retorn at a median of 18 months), healed repairs scored only 6.1 Constant points and 7.1 ASES points higher than retorn repairs, both values are below the commonly used MCIDs. The authors concluded that most patients can expect satisfactory outcomes despite a retear [7]. An earlier meta-analysis of Level I and II studies found no difference in ASES between intact and retorn repairs; strength was the clearest difference [8].

“Healed” on MRI may also not mean healed where the tendon was fixed. In a study using tantalum markers in the repaired tendon, all 13 repairs retracted from their point of fixation during the first year, by 16 mm on average, yet only 4 showed a defect on MRI [9]. The MRI retear rate is thus an imperfect measure of the tendon’s condition, and a weak predictor of how the patient will do.

A second 2026 meta-analysis, of 9 randomized trials (556 patients) of biologic grafts, found a similar structural effect from augmentation: a retear risk ratio of 0.31 and tendons 1.2 mm thicker [10]. Its abstract reports the patient-reported outcomes only as improvement from before to after surgery, which occurs with or without a graft, and concludes that greater clinical improvement with augmentation was “less consistent” [10].

The AAOS strong recommendation for patches

The 2025 AAOS guideline states that “the use of bioinductive tendon implants to augment rotator cuff repair or as an alternative to non-augmented repair can lead to lower retear rates and better patient-reported outcomes” [11]. It grades the evidence High and the recommendation Strong. By the guideline’s own definition, Strong requires two or more high-quality studies “with consistent findings” [11]. The two studies are randomized trials of the same bovine collagen implant (Regeneten); the larger one received financial support from the manufacturer [12,13].

Trial

Patients and comparison

Imaging

Patient-reported outcomes

Ruiz Ibán et al. [12,13]

124 posterosuperior tears 1–4 cm across (mean about 2 cm), retraction ≤3 cm, fully repairable; transosseous-equivalent repair with vs. without patch

Retear at 2 years 12.3% vs. 35.1%

No difference in ASES, Constant, pain or EQ-5D; ASES MCID reached by 91% vs. 88%

Camacho Chacón et al. [14]

60 supraspinatus tears ≤2.5 cm with intact rotator cable; patch instead of repair vs. sutured repair

Better tendon histology at 6 months

ASES 88 vs. 80 at 2 years, a difference below the MCID

 

The guideline’s rationale acknowledges that in the larger trial “functional outcomes did not demonstrate any differences” [11]. That trial’s 2-year report, which the guideline does not cite, is titled “a lower retear rate but similar outcomes” [13]. The smaller trial asked a different question: can a patch replace a repair in a small tear with an intact rotator cable? Its 8-point ASES difference is below the MCID [14].  The two trials do not provide strong evidence of improved clinical outcomes for patients having patches used in their cuff repair

Neither trial studied the tears for which augmentation is most often proposed. The larger trial enrolled only fully repairable tears 1 to 4 cm across, with tears averaging about 2 cm; it excluded tendons retracted more than 3 cm and muscles with Goutallier grade 3 or 4 fatty infiltration [12,13]. The smaller trial enrolled only tears of 2.5 cm or less with an intact rotator cable [14]. Massive tears and tears with poor-quality tendon, where retears are most common, were not tested.

Title: Shoulder scores over time - Description: ASES and Constant scores before and after surgery, with and without the patch, in the Ruiz Iban and Camacho Chacon trials

Figure 1. ASES and Constant scores over time, with and without the patch, in the two trials behind the AAOS strong recommendation. When the patch was added to a repair, the two groups tracked each other at every time point [12,13]. When the patch was used instead of a repair, the groups separated [14]. Ruiz Ibán values were read from the published figure; Camacho Chacón values are medians from the published tables.

The guideline lists the risks of these implants as longer operating time, possible infection and added cost. It does not mention stiffness or reoperation. It closes by calling for high-quality studies “to definitively establish the benefits of these devices” [11].

What else we know about patches

•    Partial-thickness tears. In a manufacturer-funded randomized trial of 41 patients, a patch without repair produced better WORC scores at 6 weeks and 3 months than takedown and repair. There was no difference in any patient-reported outcome at 6 or 12 months. The patch group was told to wear the sling for 1 week, the repair group for 4 to 6 weeks [15].

•    Meta-analysis. Improvement and the proportion of patients reaching the MCID after patch-augmented repair were similar to historical standard repair. The overall complication rate was 15.5% after full-thickness and 16.2% after partial-thickness repairs. There were no concurrent controls [16].

•    Matched cohort. At a minimum of 2 years, 47 patched repairs and 94 matched unpatched repairs had similar ASES (81 vs. 85), SSV (79 vs. 85) and pain scores. Reoperation for inflammation and stiffness was 9% (4/47) with the patch and 0% (0/94) without it. The authors stopped using the implant [17]. In the accompanying commentary, McAllister Nolan noted that these grafts are “heavily promoted to surgeons by industry” and recommended avoiding them for this indication [18].

•    Partial-thickness repairs. In a propensity-matched comparison, stiffness in the first 12 weeks occurred in 8 of 32 patched shoulders and 1 of 32 controls. Six patched shoulders, and no controls, required reoperation for stiffness [19]. This happened even though the controls more often had a tear takedown and repair (18 vs. 5 of 32), an operation that could be expected to cause more stiffness, not less [20].

•    Human dermal allograft in large tears. One randomized trial reports a longer follow-up. Sixty patients with 3 to 5 cm tears had repair with or without a human dermal allograft; 43 were seen at a mean of 5.7 years [21]. Retear was 9.1% with the allograft and 38.1% without it. The trial’s primary outcome, the Constant score, did not improve more with the allograft (p = 0.053). The ASES improved 13 points more with the allograft (p = 0.047), but the allograft group started 5 points lower [21]. This is a different product from the bovine implant in the AAOS strong recommendation, and the guideline rates the dermal allograft evidence as moderate [11].



A "strong" recommendation carries weight beyond the operating room [6]. A patient with a retear after an unpatched repair could point to it. A surgeon who left the patch out because the patient-reported data did not support it would have to defend that choice. Meanwhile the patient who receives a patch, becomes stiff and needs a second operation may ask why the implant was used. 

The cost is real. An economic analysis co-authored by an employee of the manufacturer assumed that the implant adds $3,641 to each repair; our meta-analysis cites $5,000 to $10,000 per case [6,22]. That analysis estimated an added $232,468 per 100 patients to obtain 18 more MRI-healed tendons [22]. That is a cost per healed tendon, not per patient with greater improvement.

A 2026 analysis, labeled "Level I evidence", concluded that the patch is “the dominant, cost-effective treatment strategy” over 10 years, saving money and adding 1.3 quality-adjusted life years per patient [23]. This is not an outcome study: no patient was followed for 10 years. It is a computer model, and its conclusion follows from its assumptions rather than from observed results. The study received grant funding from the manufacturer [23].

 

What the model assumed

What the trial on which it was based actually found [12,13]

New retears

Each year, 26% of intact unpatched repairs and 8% of intact patched repairs retear. Over 10 years, that adds up to about 95% of unpatched and 57% of patched repairs.

35% of unpatched and 12% of patched repairs had retorn at 2 years. But the retear rate drops off over the first year. Only about 9% more control repairs retore in the second year. In contrast to the assumption, the retear rate is no the same "each year".

Quality of life

Assigned from MRI status: 0.7 if intact, 0.6 if torn, values taken from an earlier publication.

Quality of life was measured directly (EQ-5D) and did not differ between groups at any time.

Reverse arthroplasty

Each year, 16% of patients with a retorn tendon go on to reverse arthroplasty, at about $34,500 each.

No patient had a reverse arthroplasty. Two had early reoperations, both in the control group, and none occurred in the second year.


Each assumption favors the patch. The model turns a modest difference in retears at 2 years into a large one at 10, gives that difference a quality-of-life cost the trial did not find, and converts it into expensive operations that did not occur. Even its own quality-of-life values cannot produce the reported gain: if every unpatched tendon were torn and every patched tendon intact for all 10 years, the difference would be less than 0.9 quality-adjusted life years, not 1.3.

Who pays also matters. In one ambulatory surgery center, use of a biologic (a dermal allograft or bioinductive implant) was the largest single driver of charges for cuff repair, adding $17,791 to a risk-adjusted $19,728 [24]. Ambulatory cuff repair is increasingly paid under fixed-rate, episode-based bundles, in which the surgeon and facility bear the financial risk of added costs [25]. When the payment for the repair is fixed, the patch comes out of the margin, and a surgeon who owns a share of the center faces a three-way pull. On one side are a strong guideline recommendation and its medicolegal weight; on another, the surgeon’s own finances; and in between, trials showing no difference that patients are likely to notice. Contracts that pay for implants separately, or consulting relationships with manufacturers, can tilt the balance the other way. None of these is a clinical reason to use a patch, or to withhold one.

Questions to ask of any patch study

Abstracts deserve particular care. Among 16 systematic reviews comparing patch-augmented with unaugmented repair, 13 (81.3%) had spin in the abstract [26]. Spin was not associated with funding (P = .36), but each methodological flaw on the AMSTAR-2 checklist was associated with 61% more types of spin [26]. One example: a 2024 meta-analysis of 5 randomized trials of dermal patches concluded in its abstract that patches “improve outcomes.” Its discussion acknowledges that the differences, 2.8 Constant points and 5.6 ASES points, did not reach the MCIDs of 4.6 and 11.1 [27].

When the results of a well-controlled study on the effectiveness of patches in cuff repair are presented, we should ask:

1.   What was the difference in patient-reported outcome between groups, and did it reach the MCID?

2.   What proportion of patients in each group reached the MCID or the patient acceptable symptom state?

3.   How many had stiffness, capsulitis or reoperation, compared with controls?

4.   Was the control a repair alone, something less (debridement), or something more (takedown and repair)?

5.   Were the rehabilitation protocols the same in both groups?

6.   Who paid for the study?

Bottom line

What is demonstrated: (1) a bovine patch placed over a sound repair lowers the MRI retear rate; (2) a patch used instead of a repair combined with faster rehabilitation may return some patients to daily activities sooner; and (3) patches are associated with more stiffness and reoperation in unconflicted series.

What is not demonstrated: that adding a patch improves comfort or function by an amount that is clinically significant. 

Most trials follow patients for only one to two years; the mean follow-up in our meta-analysis was 18 months [6]. Whether fewer retears translate into better function later, or into less cuff tear arthropathy, is not known. 


Considering..
The Northern Shrike
AKA the "Butcher Bird" because he hangs his catch on tree thorns.

The author of this post has no financial relationship with any orthopaedic company.


Follow on twitter: https://twitter.com/shoulderarth

References

[1]        Rao AJ, Saltzman BM, Harrison AK. What’s new in shoulder and elbow surgery. J Bone Joint Surg Am. 2026;108(20):1574-7. doi:10.2106/JBJS.26.00744

[2]        Al-Hourani K, Khan S, Boufadel P, et al. What’s new in sports medicine. J Bone Joint Surg Am. 2026;108(11):763-70. doi:10.2106/JBJS.25.01633

[3]        Kim YK, Kim YT, Won YS, et al. Efficacy of an autologous dermal fibroblast injection in reducing the retear rate after arthroscopic rotator cuff repair: a prospective randomized controlled trial. Am J Sports Med. 2025;53(3):592-9.

[4]        Ye Z, Chen C, Chen H, et al. Bone marrow stimulation yielded similar clinical outcomes with improved tendon healing and abduction strength compared with decortication for arthroscopic rotator cuff repair in shoulder active patients. Arthroscopy. 2025;41(8):2740-9.e3.

[5]        Schanda JE, Ullrich R, Boesmueller S, et al. Intraoperative zoledronic acid for arthroscopic rotator cuff repair: short-term results from a prospective, randomized, placebo-controlled phase II trial. Am J Sports Med. 2026;54(2):342-52.

[6]        Checketts JX, Daniels SD, Schiffman CJ, Matsen FA III, Hsu JE. Biologic augmentation improves rotator cuff integrity but not clinically significant patient outcomes: a meta-analysis of randomized controlled trials. JBJS Open Access. 2026;11:e26.00248. doi:10.2106/JBJS.OA.26.00248

[7]        Holtedahl R, Bøe B, Brox JI. The clinical impact of retears after repair of posterosuperior rotator cuff tears: a systematic review and meta-analysis. J Shoulder Elbow Surg. 2023;32:1333-46. doi:10.1016/j.jse.2023.01.014

[8]        Russell RD, Knight JR, Mulligan E, Khazzam MS. Structural integrity after rotator cuff repair does not correlate with patient function and pain: a meta-analysis. J Bone Joint Surg Am. 2014;96:265-71. doi:10.2106/JBJS.M.00265

[9]        McCarron JA, Derwin KA, Bey MJ, et al. Failure with continuity in rotator cuff repair “healing.” Am J Sports Med. 2013;41(1):134-41. doi:10.1177/0363546512459477

[10]      Amin V, Ghayyad K, Oshikoya O, Goltz D, Huffman GR. Biologic graft augmentation is associated with lower retear rates and greater tendon thickness compared with arthroscopic rotator cuff repair without augmentation: a systematic review and meta-analysis of randomized controlled trials. Arthroscopy. 2026. doi:10.1002/arj.70619

[11]      American Academy of Orthopaedic Surgeons. Management of Rotator Cuff Injuries: Evidence-Based Clinical Practice Guideline. Published August 18, 2025. https://www.aaos.org/rccpg2025

[12]      Ruiz Ibán MA, Garcia Navlet M, Moros Marco S, et al. Augmentation of a transosseous-equivalent repair in posterosuperior nonacute rotator cuff tears with a bioinductive collagen implant decreases the retear rate at 1 year: a randomized controlled trial. Arthroscopy. 2024;40(6):1760-73.

[13]      Ruiz Ibán MA, García Navlet M, Moros Marco S, et al. Augmentation of a posterosuperior cuff repair with a bovine bioinductive collagen implant shows a lower retear rate but similar outcomes compared with no augmentation: 2-year results of a randomized controlled trial. Arthroscopy. 2025;41(10):3869-79. doi:10.1016/j.arthro.2025.03.057

[14]      Camacho Chacón JA, Roda Rojo V, Martin Martinez A, et al. An isolated bioinductive repair vs sutured repair for full-thickness rotator cuff tears: 2-year results of a double blinded, randomized controlled trial. J Shoulder Elbow Surg. 2024;33(9):1894-904. doi:10.1016/j.jse.2024.03.043

[15]      Wang A, Breidahl W, Ek ET, et al. Early functional recovery is improved in patients treated with bioinductive collagen implant augmentation compared with standard arthroscopic repair of high-grade partial-thickness rotator cuff tears: a prospective randomized trial. Orthop J Sports Med. 2026;14(3):23259671261418675. doi:10.1177/23259671261418675

[16]      Warren JR, Domingo-Johnson ER, Sorensen AA, et al. Bioinductive patch as an augmentation for rotator cuff repair, a systematic review and meta-analysis. J Shoulder Elbow Surg. 2024;33(11):2515-29. doi:10.1016/j.jse.2024.05.002

[17]      Haft M, Li SS, Pearson ZC, et al. No short-term clinical benefit to bovine collagen implant augmentation in primary rotator cuff repair: a matched retrospective study. Clin Orthop Relat Res. 2025;483:442-52. doi:10.1097/CORR.0000000000003247

[18]      McAllister Nolan B. CORR Insights®: No short-term clinical benefit to bovine collagen implant augmentation in primary rotator cuff repair: a matched retrospective study. Clin Orthop Relat Res. 2025;483:453-4. doi:10.1097/CORR.0000000000003281

[19]      Yeazell S, Lutz A, Bohon H, et al. Increased stiffness and reoperation rate in partial rotator cuff repairs treated with a bovine patch: a propensity-matched trial. J Shoulder Elbow Surg. 2022;31(6 Suppl):S131-5. doi:10.1016/j.jse.2022.02.003

[20]      Yeazell S, Lutz A, Bohon H, et al. Response to Bushnell et al regarding: "Increased stiffness and reoperation rate in partial rotator cuff repairs treated with a bovine patch: a propensity-matched trial." J Shoulder Elbow Surg. 2022;31:e572-3. doi:10.1016/j.jse.2022.06.028

[21]      Lee GW, Kim JY, Lee HW, Yoon JH, Noh KC. Clinical and anatomical outcomes of arthroscopic repair of large rotator cuff tears with allograft patch augmentation: a prospective, single-blinded, randomized controlled trial with a long-term follow-up. Clin Orthop Surg. 2022;14(2):263-71. doi:10.4055/cios21135

[22]      McIntyre LF, Nherera LM, Schlegel TF. Resorbable bioinductive collagen implant is cost effective in the treatment of rotator cuff tears. Arthrosc Sports Med Rehabil. 2023;5(2):e367-74. doi:10.1016/j.asmr.2023.01.002

[23]      Hurley ET, Ruiz Ibán MÁ, Oeding JF, et al. Bio-inductive collagen implant augmentation for arthroscopic rotator cuff repair is cost-effective in medium to large tears for reducing retears: a secondary analysis of a randomized controlled trial. Arthroscopy. 2026;42:73-82. doi:10.1002/arj.70000

[24]      Morris JH, Malik AT, Hatef S, Neviaser AS, Bishop JY, Cvetanovich GL. Cost of arthroscopic rotator cuff repairs is primarily driven by procedure-level factors: a single-institution analysis of an ambulatory surgery center. Arthroscopy. 2021;37(4):1075-83. doi:10.1016/j.arthro.2020.11.033

[25]      Lu Y, Labott JR, Salmons HI IV, et al. Identifying modifiable and nonmodifiable cost drivers of ambulatory rotator cuff repair: a machine learning analysis. J Shoulder Elbow Surg. 2022;31:2262-73. doi:10.1016/j.jse.2022.04.008

[26]      Al-Badaineh M, Josan H, Imran B, et al. Spin in systematic reviews on patch-augmented rotator cuff repair: prevalence, predictors, and methodological implications. J Shoulder Elbow Surg. 2026 [Epub ahead of print]. doi:10.1016/j.jse.2026.07.030

[27]      Hurley ET, Crook BS, Danilkowicz RM, et al. Acellular collagen matrix patch augmentation of arthroscopic rotator cuff repair reduces re-tear rates: a meta-analysis of randomized control trials. Arthroscopy. 2024;40(3):941-6. doi:10.1016/j.arthro.2023.09.025

Saturday, October 17, 2026

The B2 glenoid: what surgeons are "correcting", and does "correcting" it improve the patient's outcome?




The B2 glenoid.

 A B2 glenoid is a biconcave glenoid: posterior wear has formed a second concavity (the neoglenoid) behind the original surface (the paleoglenoid), with a ridge between them, and the humeral head is decentered posteriorly onto the neoglenoid. The defining feature is the biconcavity, not a degree of retroversion [1, 2].

Axillary "truth" view. Note biconcavity and posterior decentering 

seen when arm elevated in plane of scapula



Intraoperative photo of this glenoid showing 
the pathologic posterior concavity (neoglenoid).

In brief

In a B2 shoulder the humeral head sits back on a glenoid it has worn into two concavities. Many surgeons focus on addressing glenoid version. Let's put that into perspective:

•      The goal of an anatomic arthroplasty, whether a ream-and-run or a total shoulder, is to restore the mobility and stability of the articulation, not to recreate premorbid anatomy. Rebuilding the premorbid anatomy by "restoring the native joint line" in a tight joint can leave the shoulder stiff.

•      Correcting version has not been shown to improve what the patient reports. Studies relating the version of the implanted component to the result have not found that less retroversion gives a better shoulder. In a consecutive series of 458 anatomic total shoulders with standard components and no attempt to correct version, B2 and B3 shoulders did as well as type A shoulders [3].

•      The evidence points to the importance of complete seating of the component and centering of the humeral head on the glenoid, rather than to the angle of version [10, 11, 20]. Centering the head on a well-seated glenoid component can avoid the rocking-horse loading that can lead to component loosening [1, 12, 20].

•      "Correction" of version has costs. In pooled data, eccentric "high side" reaming carried more complications and revisions than noncorrective reaming [18]. Augmented components are intended to correct retroversion; however none has yet been shown to give the patient a better functioning shoulder [3, 15, 34, 37, 38].

•      The reverse can be used in this setting [30, 36, 39, 46], but the differences reported between it and the anatomic total shoulder are small, below the minimal clinically important difference for the SST and the ASES scores [21, 22, 30, 36, 41]; the patients who received the reverse were older [30, 36].

•      Preoperative CT and patient-specific instrumentation have not been shown to reduce revision rates [47].

•      A standardized axillary "truth" view, taken with the arm elevated in the plane of the scapula, shows version, decentering, and biconcavity. The same view can be obtained after surgery to examine the pre to post operative anatomy [6, 7, 8, 9].

Two questions

The B2 glenoid has attracted more new technology than almost any other problem in shoulder arthroplasty: three-dimensional CT, planning software, patient-specific instrumentation, navigation, robotic assistance, posteriorly augmented glenoid components, augmented baseplates, and a growing use of the reverse in shoulders with an intact rotator cuff. Each is offered as a better way to manage posterior glenoid wear.


Two questions are worth asking about each of them.

•         What problem are we trying to solve?

•         What evidence shows that the proposed solution improves the patient’s comfort, function, and the durability of the arthroplasty — rather than just improving a measurement on an image?

What a B2 glenoid is

In advanced glenohumeral arthritis the humeral head often sits back on the glenoid. Over time it wears a second socket into the back of the glenoid. What remains is a biconcave surface: the original anterior socket that has not been worn (the paleoglenoid) and the newly worn posterior socket (the neoglenoid), with a ridge between them. The face of the glenoid is often retroverted, and the humeral head is decentered posteriorly onto the neoglenoid. Walch, who defined the B2, observed that "the value of the retroversion does not explain the biconcavity of the glenoid" [1].

A B3 is further along the same path. The ridge is gone and the surface is a single concavity again, but it is more retroverted, more medialized, and there is less bone left to support a component.

Type B glenoids are not rare problems. In the series from our practice they are among the most common glenoid types encountered in shoulder arthroplasty: 100 of 349 classified anatomic total shoulders (29%) were B2, and 152 (44%) were B2 or B3 [3]; 47 of 113 ream-and-runs in a recent study (42%) were B2 [4]; and in 544 concurrent cases, 46% of the ream-and-runs and 28% of the total shoulders were B2 [5].




Figure 1. The B glenoids.  Left: B1 (posterior decentering without biconcavity). Center: B2 (posterior decentering with biconcavity). Right: B3 (centering on severely retroverted and medialized glenoid).

Seeing the B2: the standardized axillary view

Glenoid pathoantomy does not fall in to discrete categories, rather there are many intermediate types--fifty shades of gray.

Figure 2. Five type arthritic glenoids on standardized axillaryviews, showing a range of retroversion, decentering, and biconcavity.


The standardized axillary view, which we call the "truth" view, is a practical way of characterizing the glenoid articular surface and humeral centering on it. Importantly, this view can be used before and sequentially after shoulder arthroplasty without the cost and radiation of a CT scan. It is taken with the patient supine and the arm in neutral rotation, elevated 60 degrees in the plane of the scapula. The beam is directed from the axilla, parallel to the blade of the scapula, toward a cassette held over the top of the shoulder. The film is adequate when the spinoglenoid notch is clearly seen [6].

Figure 3. The axillary “truth” view.From Rockwood and Matsen’s The Shoulder, 6th edition, Figure 16-32.


The position of the arm matters because where the head sits on the glenoid depends on it. In an open MRI study of 20 arthritic shoulders, 10 with primary osteoarthritis and 10 with cuff tear arthropathy, imaged in different positions of elevation in the scapular plane, 5 showed posterior decentering at 30 degrees of abduction and 13 at 90 degrees. The authors called this "functional decentering" and pointed out that it “can often not be detected by standard radiologic workup with the arm in the neutral position.” The densest subchondral bone on the glenoid was where the head sat [7]. A CT or MRI taken with the arm at the side shows only the decentering that persists in that position. The two images below were taken on the same patient the same day. MRI to the right shows a centered head and the axillary "truth" view shows dramatic decentering [6].


The axillary view shows the head on the glenoid 

with the arm elevated in a position of function.


From this one view the surgeon can read three things:

•         Glenoid version: the angle between a line along the body of the scapula and a line joining the anterior and posterior rims of the glenoid. Retroversion is 90 degrees minus that angle.


 •         Biconcavity: whether posterior wear has formed a second socket, and how much of the glenoid face lies on each side of the ridge between them.


•         Decentering: the percentage of the humeral head lying behind a line perpendicular to the midpoint of the glenoid face, as Walch defined it (see below) [1].

    



These readings are reproducible. In 127 shoulders, two independent observers, one of them a resident without special training in shoulder surgery, agreed closely on glenoid version (r = 0.81) and glenoid type (weighted kappa 0.859). Each reading took less than two minutes and needed no CT, reformatting or software. The proportions of type A and type B glenoids fell within the ranges reported in CT series [6].

What the view offers above all is the same view before and after surgery. Notably it does not give the same number for version as a CT. In one comparison of 50 shoulders imaged both ways, retroversion read greater on the axillary view in 86%, by a mean of 6.5 degrees. While CT is widely used to assess the shoulder before surgery, postoperative imaging is most often done with plain radiographs [8]. 

A systematic review found that 35% of studies measuring postoperative version used a different imaging method after surgery than before making comparison difficult [9].

Standardized axillary views taken the same way before and after surgery measure the same thing on both occasions, at a fraction of the cost and radiation of CT [6].


Figure 4. Standardized axillary views of the same shoulder before (left) and after (right) a ream-and-run with an anteriorly eccentric humeral head. Before surgery the head is severely decentered posteriorly on a biconcave glenoid; afterward it is recentered on the glenoid. The same value applies to the anatomic total shoulder.



The classification that gave us the B2 was built on CT, but CT is not necessarily the "gold standard," with variations related to patient positioning, imaging technique and slice selection. 

Walch and colleagues read 113 osteoarthritic shoulders on axial slices taken with the patient supine and the arm at the side in neutral rotation. Fifteen percent were B2, with a mean retroversion of 23 degrees. The authors observed that the study showed "a wide range of glenoid polymorphism" [1]. Surgeons reading CT scans have not always agreed on which type a glenoid is. In later studies using the full classification, agreement between observers ranged from fair (kappa 0.37) to moderate (kappa 0.60); Walch's original figure of 0.65 to 0.70 was for the three main types alone. In one comparison, MRI identified fewer B2 glenoids than CT did, and its authors suggested that MRI may not show biconcavity reliably [2].


Decentering and humeroscapular alignment are different measurements

Unfortunately, the B2 literature uses one word, "subluxation", for two different measurements of where the humeral head sits. We prefer to avoid the word "subluxation" and identify each measurement for what it refers the head to.

Humeroscapular alignment refers the humeral head position to the plane of the scapular body. A line is drawn along the scapular body to the midpoint of the glenoid face; the position of the center of the humeral head is expressed as the percentage of the head lying posterior to that line. Fifty percent means the head lies squarely on the scapular axis; higher values mean it sits posteriorly. Confusingly, this is what most current reports mean by "subluxation", but it does not indicate the degree of decentering. For example, in a B3 glenoid the head will lie behind the plane of the scapula, but the head is not decentered on the face of the glenoid.

Decentering refers the head to the glenoid. A line is drawn perpendicular to the midpoint of the glenoid face, and the percentage of the humeral head lying behind that line is measured; 50% means the head is centered on the glenoid. This was in fact Walch's original measure (see figure above) [1]. Some reports express decentering relative to zero instead: the distance of the center of the head from the same line as a percentage of the head's diameter, so that 0% is centered. It is the same measurement as the Walch percentage less 50; a head 64% behind the line is decentered 14% [10, 11]. Papers also differ in the sign they give to posterior decentering: some report it as a positive number, others as a negative one. 



Figure 5. In the retroverted B3 glenoid, the humeral head center (yellow) commonly lies centered on the perpendicular bisector of the glenoid face (green line). As a result of the glenoid retroversion, the head center lies substantially posterior to the plane of the scapula (blue line).


Humeroscapular alignment combines two things: the version of the glenoid and the position of the head on it. Decentering isolates the second, which is the relationship between the two joint surfaces and the thing the rocking-horse concern is about.

Version and centering are different. In 33 arthroplasties requiring an anteriorly eccentric head, preoperative decentering bore no relationship to preoperative glenoid version (R² = 0.0009) [12]. In 40 B2 glenoids treated without changing version, decentering was corrected from −14% to −1% while version stayed at −21 to −19 degrees [13]. In 30 shoulders treated with the ream-and-run for the combination of retroversion, posterior decentering, and biconcavity, glenoid version did not change, while the centering of the humeral head on the glenoid was largely corrected [14]. The head can be recentered on the glenoid without changing version. On the other hand, one augmented-component series reported humeroscapular alignment fell from 69.1% to 53.5%, and decentering from 5.8% to −3.0% [15].

None of this would matter much if the reports kept the two apart. Many do not. Most augmented-component and reverse series report humeroscapular alignment and call it subluxation; the series from our group report decentering; and some report a quantity called subluxation on yet another scale, such as the series in which it fell from 66% to 12% [16] — a value that cannot be on the scapular scale, where 50% is centered. 

Numbers using the same word cannot be compared across papers without checking which reference line was used. Neither measure has been shown to predict the result. In a 5-year series with non-corrective reaming, the final SST score and its change were not correlated with preoperative decentering (P = .398) or with humeroscapular alignment (P = .718). In patients with B1 and B2 glenoids, there were no differences in outcomes between patients with postoperative retroversion measurements of more or less than 15 degrees [11].

Where the concern about the B2 came from

A retroverted, biconcave socket with the head sitting back on it could load a glenoid component eccentrically — the rocking-horse mechanism — and could lead to early loosening and to continued posterior instability [10].

Figure 6. Left: eccentric loading of the glenoid exposes it to risk through the "rocking horse" mechanism (from Matsen FA III, Lippitt SB. Shoulder Surgery: Principles and Procedures. Philadelphia: Saunders; 2004:508). Right: a clinical example of rocking-horse loosening of a glenoid component.

That concern has clinical support. Walch and colleagues reported on 92 total shoulder arthroplasties performed for biconcave glenoids, most treated with asymmetric reaming, and found 15 revisions (16%) at a mean of 77 months, 6 of them for glenoid loosening [17]. Findings like these suggested that the glenoid component should be placed in less than 15 degrees of retroversion and center the head.

The rocking-horse mechanism concerns the second part of that target. By centering the humeral head on a well-seated glenoid component, the risk of rocking-horse loosening can be minimized whether glenoid version is changed or not.

Does correcting version improve what the patient reports?

Here is what has been found in patients in whom no specific effort was made to change glenoid version.

•      At two years, glenoid components implanted in 15 degrees or more of retroversion did not produce lower Simple Shoulder Test (SST) scores, less improvement, more radiolucency, or more revision than components implanted in less retroversion. Among the 39 type B glenoids in that series, the retroverted components improved by 7.8 SST points against 5.3 for the non-retroverted — a difference in the direction opposite to the one expected by the advocates of version correction [10].

•      At a minimum of five years (mean, eight years) in 210 shoulders treated with conservative reaming and standard components, the final SST score, the change in SST score, and the percentage of maximum possible improvement were not correlated with preoperative or postoperative humeral head centering, with Walch classification, or with glenoid version. Among the 110 B1 and B2 shoulders, outcomes did not differ above and below 15 degrees of postoperative retroversion [11].

•      A systematic review and meta-analysis of 15 studies and 1,190 shoulders did not find published evidence that a glenoid component placed in less than 15 degrees of retroversion produced better patient-reported outcome scores, better motion, fewer complications, or fewer revisions than one placed in 15 degrees or more [18].

•      A second systematic review, from a different group, reached the same conclusion by a different route. Rutledge and colleagues identified 16 studies and 1,211 shoulders; 13 of the studies were Level IV. Of the 11 that analyzed clinical outcomes, 8 found no association between preoperative or postoperative retroversion and the result. The authors concluded that the evidence is insufficient to show that version affects outcomes independently of other features of the deformity and that it does not establish that retroversion routinely needs to be corrected [19].

These studies have not shown that correcting version improves the comfort or function the patient reports. That is different from showing that version does not matter. What can be said is that the benefit assumed for version correction has not yet been demonstrated in patient-reported outcomes.

The same meta-analysis reports a radiographic finding in the direction opposite to what some may have suspected. Shoulders with 15 degrees or more of postoperative retroversion were more likely to have no radiolucency at all around the component — a Lazarus grade of 0 — than shoulders with less than 15 degrees (odds ratio 0.38 for the group under 15 degrees, P = .0002) [18]. These are pooled retrospective cohorts that differ in surgical technique, so the comparison cannot show that retroversion protects the component. What it shows is that the expected association was not found.

The 5-year series points to something that may matter. Among the 51 shoulders with radiographs at a minimum of five years, 15 (29%) had components that met the radiographic definition of loose. On multivariable analysis the two variables most strongly associated with that finding were incomplete seating of the component (odds ratio 3.3, P = .082) and preoperative humeral head decentering (odds ratio 2.8, P = .127), rather than postoperative version (odds ratio 1.1, P = .311); none of the three reached statistical significance [11].

A group that does correct version has reported the same pattern. Harold and colleagues followed B2 glenoids treated with partially corrective high-side reaming for a mean of 8.6 years. Three of 59 shoulders (5.1%) had been revised, and 3 of the 30 with final radiographs had components that had failed radiographically without revision. Failure was associated with how well the component was seated at surgery and with posterior displacement of the head that recurred afterward (21% against 7.0% at final follow-up). It was not associated with preoperative retroversion, inclination, or posterior displacement of the head. In this series the radiographic finding did associate with patient outcome: the shoulders with failed components had a mean ASES score of 73 against 88, and more pain (2.1 against 0.8) [20]. That 15-point ASES difference exceeds the 13.6-point minimal clinically important difference derived in one registry [21], though not the 20.9 points derived in another [22]. It points the same way as the 5-year series: seating and centering seem to loom large, rather than the angle.

The 2-year series reports one consequence of retroversion. The fluted central peg perforated the anterior glenoid vault in 52% of the retroverted shoulders against 18% of the others, and in the type B subgroup in 53% against 17%. That series did not test whether perforation affected the result; it points instead to earlier reports in which perforation was not associated with inferior clinical or radiographic outcomes [10]. Since we intentionally perforate the glenoid vault in performing a reverse total shoulder, perhaps we should be less concerned about perforation in an anatomic.

A commentary published alongside that series sets up the comparison worth having. Two surgeons used the same glenoid implant. Ho and colleagues, aiming for a component perpendicular to the plane of the scapula, reported central peg osteolysis in 20 of 66 shoulders (30%) at a mean of 3.8 years; the series above, in which no attempt was made to change version, reported 10 of 71 (14%) at a mean of 2.5 years [10]. The commentator asks whether the additional reaming accounts for the difference, notes that the two groups also differed in how the peg holes were prepared and in the use of an anteriorly eccentric humeral head, and observes that single-surgeon series of this size will differ for reasons that are difficult to separate [23]. The follow-up is not the same in the two reports and the comparison is not controlled. However, the question is the right one.

What has been reported for different approaches to glenoid version.

Conservative, non- corrective glenoid reaming with a standard all-polyethylene component

The residual cartilage over the anterior glenoid is removed, the ridge between the paleoglenoid and the neoglenoid is taken down with a burr, and the reamer is then oriented equidistant from the anterior and posterior edges of the glenoid so as to remove the least possible bone. Version change is not the target; a single, supported concavity that matches the back of the component is.

In 66 shoulders with B2 (n = 40) and B3 (n = 26) glenoids treated this way, mean version was essentially unchanged (−21 to −19 degrees for the B2 glenoids, P = .267; −26 to −23 degrees for the B3 glenoids, P = .129). Humeral head decentering was corrected all the same, from −14% to −1% in the B2 glenoids and from −4% to −1% in the B3 glenoids. The SST improved from 3.2 to 9.9 and from 3.0 to 9.4 points. Osseous ingrowth between the flanges of the central peg was seen in 83% of the B2 and 81% of the B3 glenoids. None of these results was inferior to those for the other glenoid types treated by the same surgeon over the same period [13].

A 2026 systematic review of anatomic arthroplasty in B2 and B3 glenoids, pooling six studies and 443 patients treated with a mixture of techniques, found that both groups improved in patient-reported outcomes and pain. Radiolucency was reported more often in the B2 glenoids (31%) than in the B3 (22%), and the B3 glenoids remained more medialized after surgery [24]. In these pooled series, the more advanced deformity was not the one with more radiolucency.

A second group has reported the same approach from a different starting point. In 79 shoulders with mild to moderate B2 or B3 deformity — defined as the ability to template a component within 10 degrees of premorbid version — in which the surgeon had an augmented component available and chose a standard one, the median Penn Shoulder Score at a median of 4.3 years was 96, posterior displacement of the humeral head fell from 66% to 12%, and grade-1 anchor peg osteolysis was present in 8 of 79 (10%). Walch classification, preoperative version, inclination, and joint-line medialization were not significantly associated with the Penn score or with osteolysis, and osteolysis was not associated with a lower Penn score [16].

When the head decenters posteriorly by more than 50% of the width of the glenoid with trial components in place, an anteriorly eccentric humeral head can recenter it: in 33 such arthroplasties, radiographic decentering fell from 10.4% to 0.9% and the SST improved from 4.8 to 10.0, with no postoperative instability [12]. Two details from that series are worth taking to the operating room. Preoperative decentering did not correlate with preoperative glenoid version (R² = 0.0009), and a third of the shoulders that needed an eccentric head had shown little or no decentering on preoperative imaging — the instability appeared only after exposure, capsular release, and osteophyte resection. The decision belongs at the trial, not on the scan.

 

Figure 7. Posterior translation of the humeral head by more than 50% of the width of the glenoid with the trial components in place at surgery. This is the finding that may call for an anteriorly eccentric humeral head.


A second group has reported the same use of the eccentric head in B2 glenoids. In 20 patients in whom the head was rotated anteriorly for excessive posterior decentering found at surgery, radiographic decentering fell from 9.9% to 0.5%, pain, ASES, and SST scores improved significantly at a mean of 48 months, and no shoulder was revised [25].

Asymmetric (high-side) reaming

In a single-surgeon series of 85 shoulders followed for a mean of 9.4 years, survivorship of B2 glenoids treated with asymmetric reaming was 97.6% at 5 years and 94.1% at 10 years, compared with 97.6% and 91.9% for type A glenoids, with no significant difference in revision rate [26]. That series also reports 15-year figures of 73.3% and 83.5%. Those two numbers cannot support a comparison. Only two shoulders in each group remained at risk at 15 years, and the authors state that the entire B2 decline is produced by a single revision at 12.3 years: immediately before it, survivorship was 85.5% for the B2 glenoids against 83.5% for the type A.

Series from other centers with similar follow-up report a wider range. Gerber's group reported 32 shoulders with milder B2 glenoids (mean version −14 degrees) treated with asymmetric reaming limited to 10 degrees of correction and followed for a mean of 9.2 years. Clinical scores improved substantially. The complication rate was 15.6% and the revision rate 12.5%; survivorship free of revision was 94% at 5 years and 85% at 10, and survivorship free of advanced glenoid loosening was 91% and 84% [27]. The Harold series described above reported 5.1% revision at a mean of 8.6 years [20]. The series are small, and none has a comparison group treated without correction.

The cost of high-side reaming is glenoid bone loss. A computational study found that correcting version by eccentric reaming compromises the quality of the bone that remains in B2 glenoids [28], and a simulation study found a high risk of vault perforation when correction is carried far [29]. The meta-analysis above bears on this as well: across the pooled cohorts, shoulders treated with eccentric reaming had a higher complication rate (odds ratio 3.2) and a higher revision rate (odds ratio 6.2) than those treated with noncorrective reaming [18]. In the 5-year series, among the B1 and B2 shoulders, the 12 in which version was changed by more than 10 degrees improved by 4.6 SST points, against 6.0 points in the 69 changed by 10 degrees or less; that difference did not reach significance (P = .134) [11].

A systematic review of 16 studies covering 414 anatomic arthroplasties and 78 reverses performed for B2 glenoids reports better figures for eccentric reaming: a complication rate of 5.6% (5 of 89 shoulders) and a revision rate of 0.9% (1 of 116) among the shoulders in which version was corrected to within 10 degrees of neutral. That second number carries a caveat: the 92 shoulders of the Walch series — the largest eccentric-reaming cohort in the review, and the one reporting a 16.3% revision rate — could not be placed in the eccentric-reaming subgroup, because that report did not separate out the shoulders that also received a bone graft. They were assigned instead to a subgroup labeled unspecified, whose revision rate is 16.3%. The 0.9% figure describes eccentric reaming with its largest and least favorable series removed from the numerator and the denominator both [30].

A 2024 systematic review of 779 B2 shoulders reports that complications after eccentric reaming fell from 13.2% in series published before 2012 to 3.3% in those published after [31]. The later series were followed for less time (a mean of 51 against 59 months), and techniques, implants, and patient selection all changed over the same period.

Whenever correction is undertaken, a modest one costs less bone.

Posteriorly augmented glenoid components

These components strive to correct retroversion and re-center the head while removing less anterior bone. In pooled data, shoulders treated with posterior augments were more likely to have no radiolucency at all than those treated with either eccentric or noncorrective reaming [18].

The clinical evidence is harder to read. An early systematic review of 239 B2 shoulders reported revision rates of 15.6% for asymmetric reaming, 9.5% for posterior bone grafting, and 0% for posteriorly augmented components. Two figures from the same review qualify the third: mean follow-up in the augmented group was 42 months, and that group had the highest rate of radiolucent lines of the three techniques, at 64.7%, against 28% for asymmetric reaming and 45% for bone grafting [32].

Two series report what augments do over the first few years. With a stepped augment, Ho and colleagues reported 71 shoulders at a median of 2.4 years: version, humeral head centering, motion, and the Penn Shoulder Score all improved. Persistent posterior displacement of the head was associated with greater postoperative retroversion and with fatty infiltration of the teres minor; central peg osteolysis was associated with preoperative joint-line medialization and posterior bone loss; and, after adjustment, a lower Penn score was associated with greater preoperative posterior displacement of the head [33]. With a biconvex augment, a seven-center series reported 86 of 110 consecutive patients at a mean of 35 months. Version was corrected from 19.3 to 7.4 degrees, humeroscapular alignment fell from 69.1% to 53.5%, the ASES score rose from 49.8 to 86.7, 79 of the 86 components showed no radiolucency, and one shoulder was revised, for infection with loosening [15]. Both series show the measurement corrected and the patient improved. Neither has a comparison group, so neither can say whether the patient improved more than with a standard component. One finding in Ho's series concerns something the augment cannot change: the lower Penn scores varied with the posterior displacement of the head that the patient had preoperatively.

Two later reports carry longer follow-up. In B3 glenoids at mid- to long-term follow-up, augmented and standard components did not differ in mean ASES score (93.3 vs. 85.7, P = .217), satisfaction (95.6% vs. 96.8%), forward elevation, or external rotation, and no patient in either group underwent revision [34]. In a prospective series of 10 patients followed with CT at 5 years, augmented components held their correction of both version and head position, the mean Constant score was 78.2, and all 10 patients were satisfied — while 5 of the 10 had CT signs of aseptic glenoid loosening [35].

The B2 systematic review cited in the previous section is worth reading for what it reports about improvement rather than final score. Its augmented subgroup reached good final values — a mean Constant score of 77.4 and a mean ASES score of 90.3 — while recording the lowest mean improvement of any group in the review on both instruments, 36.1 and 47.6 points. Its complication rate was 10.5%, most often posterior displacement of the humeral head [30]. Patients who start higher finish higher.

The most recent pooled analysis, of 36 studies of anatomic and reverse arthroplasty in B2 and B3 glenoids, reports that among the anatomic arthroplasties, posteriorly augmented components were associated with lower complication and revision rates than eccentric or noncorrective reaming [36]. It compares revision rates across series with different lengths of follow-up, and the augmented series have been the shortest: a mean of 42 months in one review and 32.7 months in another, which reported a 2.8% complication rate for augments [32, 31]. Revisions after anatomic arthroplasty accumulate with time. Until the groups are followed for the same length of time, a lower revision rate is not yet evidence of greater durability.

Two more reports bear directly on the question. In a case-matched series from one institution, 37 shoulders with a full-wedge augment and 37 with a standard component were followed for a mean of 3.2 years. The augmented group had more B2 and B3 glenoids (86% against 51%). The two groups improved by similar amounts on every measure of motion and outcome — the ASES score by 41.5 points against 44.6 (P = .5) — and had similar rates of glenoid lucency (54% against 46%) and reoperation (5% against 3%). The 16-degree augment, used in 4 shoulders, had a higher mean Lazarus score than the 8-degree augment (4.2 against 1.1) and is no longer used at that institution; with it excluded, no augmented component required revision [37].

In the second, a stepped augment was used in 29 B2 and 21 B3 glenoids and compared with a standard component in 42 A1 glenoids, with CT before surgery, within 3 months, and at a mean of 2.3 years. Penn Shoulder Scores at follow-up did not differ (median 95.0 for A1, 97.4 for B2, and 96.7 for B3). Central peg osteolysis was found in 5% of the A1, 10% of the B2, and 29% of the B3 shoulders (P = .028). After surgery the head was as well centered on the glenoid in the B2 shoulders as in the A1, but sat further back relative to the scapula, because the B2 components were left in more retroversion [38]. The comparison is between an augment in a worn glenoid and a standard component in an unworn one. It does not show what a standard component would have done in the same B2 shoulders.

The comparison an augment has to win is against a standard component placed without correcting version. In the consecutive series of 458 anatomic total shoulders described below, done that way, the 152 B2 and B3 shoulders did as well as the 162 type A shoulders: final SST 9.5 against 9.1, percentage of maximal possible improvement 73% against 67%, and revision 1.3% against 4.3% [3]. An augment would have to improve on that.

Augmented components correct the measurement reliably. No report to date has shown that they give the patient better comfort or function than a standard component.

Augments, corrective reaming, or neither

No randomized trial and no same-surgeon cohort has compared posterior augments with corrective reaming for the B2 glenoid. The comparisons that exist are made across series, from different surgeons, implants, and eras.

The meta-analysis described above is the most direct. It could not compare the techniques on patient-reported outcomes, because fewer than three cohorts in each group reported the same score; the postoperative ASES of 86.7 for augments comes from a single series of 86 shoulders. Augments did not differ from eccentric reaming in complications (P = .322) or in revision (P = .225). On the radiograph, augments were more likely than eccentric reaming to show no radiolucency at all (odds ratio 15.7) and to be fully seated (odds ratio 3.0), and less likely to show bone growth between the flanges of the central peg (odds ratio 0.07) [18]. The pooled findings favoring augments on revision [36, 32] come from the shortest follow-up in the literature, as discussed above.

The one comparison between techniques in that meta-analysis to reach significance on complications and revision did not involve augments at all. Eccentric reaming had more complications (odds ratio 3.2) and more revisions (odds ratio 6.2) than noncorrective reaming [18]. On the evidence available, neither method of correcting version has been shown to give the patient a better result than the other. Neither has been shown to give a better result than leaving version alone. The trial that would settle the question would assign B2 shoulders to an augment, to eccentric reaming, or to noncorrective reaming, and would measure what the patients report at five years or more.

Reverse total shoulder arthroplasty

The strongest argument for the reverse in this setting is durability over time. In a single-surgeon comparison of eccentric wear patterns with an intact cuff, the anatomic group treated with high-side reaming did better at two years (ASES 85 vs. 80, SST 10 vs. 9.6, forward elevation 162 vs. 151 degrees, satisfaction 95% vs. 93%). By a minimum of seven years the picture had reversed on some measures: the reverse group had a higher ASES score (80 vs. 77), a higher SST score (9.4 vs. 8), and satisfaction of 95% against 82%, and 8% of the anatomic cohort had been revised against 2% of the reverse cohort. The anatomic group kept better external rotation (45 vs. 41 degrees) and internal rotation (74% vs. 54% with full internal rotation) [39].

The operation was chosen by the surgeon at the time of surgery rather than assigned, and the reverse cohort started with more deformity (mean retroversion 23 vs. 17 degrees; mean posterior displacement of the head 78% vs. 69%), which the authors identify as a possible selection bias. Of the original 242 shoulders, 194 were available at final follow-up. And the differences favoring the reverse at final follow-up were 3 ASES points and 1.4 SST points.

Whether differences of that size are large enough for a patient to notice is a question the study does not take up, but the published thresholds answer it. Using an anchor-based method in 326 shoulder arthroplasties, the minimal clinically important difference was 20.9 points for the ASES and 2.4 points for the SST [22]. An analysis of 1,856 arthroplasties from an industry-maintained multicenter registry put the thresholds lower, at 13.6 ASES points and 1.5 SST points [21], and set the substantial clinical benefit — the improvement that separates the patients who called the result much better from those who called it unchanged or worse — at 31.5 ASES points and 3.4 SST points [40]. A 3-point ASES difference falls below the lowest of these thresholds by a factor of four, below the lowest prosthesis-specific value published anywhere — 10.3 for the reverse in that same registry — by more than three, and below substantial clinical benefit by a factor of ten.

The SST difference is best read against a threshold specific to the operation, because the threshold is not the same for every operation. In 887 arthroplasties the SST minimal clinically important difference was 2.3 overall, but 1.6 for the anatomic total shoulder, 2.6 for the ream-and-run, and 3.7 for the reverse [41]. A 1.4-point difference is smaller than the threshold for either of the operations being compared, and it is less than half the threshold for the reverse — the operation the difference favors. One published value does match it: 1.4 for the reverse in that same registry [21], which is the lowest figure reported anywhere for that operation, against 2.9 and 3.7 elsewhere [22, 41]. Matching the lowest threshold published anywhere is not the same as showing a difference the patient would notice.

There is a further reason these thresholds understate what this comparison would have to exceed. The registry that produced the most permissive of them also reports them stratified by length of follow-up, and both rise as follow-up lengthens. Beyond 72 months the SST minimal clinically important difference is 3.3 and the substantial clinical benefit 5.7, against pooled values of 1.5 and 3.4; the ASES threshold is 21.7 against 13.6 [21, 40]. The comparison above is reported at a minimum of seven years. Measured against the values the same investigators derived from the same patients at that length of follow-up, a 1.4-point SST difference falls short by a factor of more than two and a 3-point ASES difference by a factor of seven.

These values were derived for improvement within a patient rather than for a difference between two groups, which is a distinct quantity. They are also less precise than their decimal places suggest. In the same registry table that gives 1.4 for the SST after the reverse, the Constant threshold for that operation is −0.3, and the thresholds for external rotation, abduction, and forward flexion are −5.3, −1.9, and −2.9 degrees [21]. A negative threshold means the patients who called themselves better had improved less than the patients who called themselves unchanged — the method returning noise in a subgroup rather than a measurement. Values carried to one decimal place and applied across studies deserve to be read with that in mind. But no reading of them turns 3 ASES points and 1.4 SST points into something a patient could feel.

A multicenter matched-cohort analysis of B2 and B3 shoulders puts the same comparison in terms of the minimal clinically important difference. Most patients reached the MCID with either operation (anatomic 95.0%, reverse 98.0%, P = .436), 82% and 90% respectively reached the threshold for substantial clinical benefit (P = .292), and overall complication rates did not differ (P = .781). Pain scores were lower after the reverse; internal rotation was better after the anatomic [42]. The difference between the two operations is small next to the difference either one makes for the patient.

The pooled evidence is thinner than the confidence with which the reverse is now offered for this problem. In that same systematic review, the entire published experience of the reverse for B2 shoulders with an intact cuff came to 78 shoulders across five studies at a mean follow-up of 44.8 months. The pooled complication rate was 6%, with a confidence interval running from 0% to 28%, and the pooled revision rate 1%, with an interval from 0% to 15% — both calculated from two studies and 43 shoulders. Improvement in the ASES score differed between the two operations by a single point, 49.2 for the reverse against 48.2 for the anatomic. The Constant score improved by 7.8 points more after the reverse, which does exceed the minimal clinically important difference for that instrument, 5.7 points, and falls well short of its substantial clinical benefit of 19.1 [21, 40]. And the patients receiving the reverse were nine years older, 72.8 against 63.7 [30].

A larger, updated review has since been published. Aleisawi and colleagues pooled 36 studies of B2 and B3 glenoids with an intact cuff: 1,349 anatomic and 478 reverse arthroplasties, followed for a mean of 4.9 and 4.2 years, in patients with a mean age of 68 and 72. Gains in motion were similar. Mean improvement in the ASES score was 44 points after the anatomic and 50 after the reverse, and in the Constant score 43 and 46. Pooled complication rates were 7.8% and 4.4%, and revision rates 5.2% and 1.6% [36]. The authors concluded that both operations are effective and that the anatomic carries a modestly higher risk of complication and revision.

A 6-point difference in ASES improvement is below every ASES threshold cited above. The difference in revision rate is the more important finding and deserves to be taken seriously. Two things belong beside it. The reverse groups were followed for less time, in patients four years older. And a revision rate counts operations performed, not shoulders that have failed. A failed anatomic arthroplasty can be converted to a reverse; the options after a failed reverse are fewer and less attractive. That revision rates may therefore understate failure of the reverse is an inference, not a finding, and it is one more reason to compare the two operations by what the patients report.

Figure 8. ASES points for B2 and B3 shoulders with an intact cuff. Each operation improves the score by more than the substantial clinical benefit; the reported differences between the two operations fall below every published minimal clinically important difference.

For an active patient in their sixties with an intact cuff, the reverse permanently changes the mechanics of the shoulder, gives up some internal rotation, and commits the patient to a construct whose behavior at 15 and 20 years is not yet known.

The more active patient

For patients who prefer to avoid a polyethylene glenoid component altogether, the ream-and-run — concentric reaming of the glenoid combined with a humeral hemiarthroplasty — remains an option for those who understand the longer and more demanding rehabilitation. The anteriorly eccentric humeral head applies here in the same way it does to the total shoulder; in the series above, 24 of the 33 arthroplasties were hemiarthroplasties with nonprosthetic glenoid arthroplasty [12].

Durability at ten years has now been reported. Of 127 consecutive patients eligible for a minimum 10-year survey, 63 (50%) responded: 34 ream-and-run and 29 anatomic total shoulders. In the ream-and-run group the SST improved from 5.4 to 10.3 and the pain score from 6.5 to 0.9, with a mean of 83% of the maximum possible improvement. Twenty-eight of the 34 (82%) exceeded the ream-and-run threshold of 2.6 SST points, and 27 (79%) exceeded the corresponding threshold of 38.2% of maximum possible improvement [41, 43]. Five patients (15%) were reoperated: four open revisions, at 6, 7, 27, and 72 months, each to another hemiarthroplasty, and one manipulation under anesthesia at 6 months. None had humeral loosening and none was converted to a total shoulder. In the total shoulder group the SST improved from 3.8 to 8.9 and the pain score from 6.6 to 1.2, and no patient was reoperated [43].

The most useful number in that report is one the series takes from itself. The mean SST at ten years, 10.3, is the same as the mean SST at two years in an earlier cohort of 101 ream-and-run patients, and the reoperation rate is essentially the same as well, 14% at two years against 15% at ten. Revision after this operation happens early; the shoulders that get past two years appear to hold what they gained. The proportion of patients exceeding the threshold holds as well: 84% of 330 ream-and-run patients exceeded it at two years, against 82% at ten [41, 43].

The percentage of maximum possible improvement is worth attention in this operation in particular. Ream-and-run patients come to surgery with more function than any other arthroplasty group — a mean preoperative SST of 5.0, against 1.7 for the reverse — so they have less room to gain in absolute points, and an absolute threshold understates what they get. The threshold for maximum possible improvement runs the other way for the same reason: 38.2% for the ream-and-run against 21.8% for the anatomic total shoulder [41].

What that report cannot do is compare the two operations. The ream-and-run patients were younger (60 vs. 68 years), 97% male against 41%, and healthier by ASA class. The comparison that would settle the question — patient-reported comfort and function against the alternatives, in patients alike enough to be compared — has not been made.

Two further reports bear on the B2 shoulder in particular. In 201 ream-and-run arthroplasties followed for a mean of 7.6 years, the most common glenoid morphology was B2, at 44%, with another 15% B1. The SST improved from 4.9 to 10.2, 82% of patients exceeded the threshold, and 11% underwent open revision. Glenoid morphology was not associated with whether a patient exceeded the threshold, and it was not associated with revision. What was associated with revision was youth: the patients who returned to the operating room averaged 54 years against 60 for those who did not [44].

The question this operation always raises is what a metal head does to reamed bone over time. In 113 shoulders with comparable serial radiographs at a mean of 6.7 years, the mean total glenoid wear was 2.9 mm — about 0.3 mm per year, but not evenly distributed. Wear ran at roughly 0.6 mm per year over the first four years and 0.2 mm per year between four and ten, plateauing at around 3 to 3.5 mm. Eighty-one percent of shoulders wore 5 mm or less, 13% between 5 and 10 mm, and 5% more than 10 mm. Change in SST and pain scores did not differ between the shoulders with mild wear and those with moderate or severe wear. Open revision did: 24% against 8%. B- and C-type glenoids were more common among the shoulders that wore more, but glenoid type did not survive multivariable analysis; younger age and the absence of prior shoulder surgery did [4].


The B2 shoulder in each of the three operations

No study has compared the ream-and-run, the anatomic total shoulder, and the reverse in B2 shoulders. What can be done is to set side by side what each operation has reported for B2 shoulders in particular, and who received it.

Ream-and-run. The B2 is the most common glenoid among the patients who choose this operation. In 544 concurrent ream-and-run and total shoulder arthroplasties at one institution, 46% of the ream-and-run shoulders were B2 against 28% of the total shoulders, and retroversion was greater (19 against 15 degrees). At two years the SST was 10.0 and 9.5 and the percentage of maximum possible improvement 72% and 73% [5]. The 30 shoulders with retroversion, posterior decentering, and biconcavity described above improved from an SST of 5 to 10 at a mean of 3 years, with no posterior instability; two were revised to a total shoulder within the first year because the patients were dissatisfied with the rehabilitation [14]. In 201 ream-and-run arthroplasties, 44% of them B2, glenoid morphology was not associated with outcome at a mean of 7.6 years [44].

Anatomic total shoulder. Without changing version: in a consecutive single-surgeon series of 458 anatomic total shoulders, the glenoid was reamed to a single concavity without effort to correct retroversion and a standard, non-augmented all-polyethylene component was used. At a mean follow-up of 6.7 years, the 100 B2 shoulders had the highest final SST (9.7) and percentage of maximal possible improvement (75%) of any glenoid type, and the B2 and B3 shoulders together were revised at 1.3% against 4.3% for type A (P = .307) [3]. In 40 B2 glenoids the SST improved from 3.2 to 9.9 [13], and among the B1 and B2 shoulders of the 5-year series, outcome did not differ above and below 15 degrees of postoperative retroversion [11]. A second group reported 51 B2 glenoids treated with noncorrective concentric reaming, 45 of them followed for a mean of 4.9 years: the ASES score improved from 52.5 to 79.6, survivorship was 95%, and reoperation is given as 4 patients in the abstract and 6 (11.8%) in the results [45]. With corrective reaming, the reports above range from 16% revision at a mean of 77 months [17] to survivorship of 85% to 94% at ten years [26, 27], and 5.1% revision at a mean of 8.6 years [20]. The augmented-component series do not yet extend beyond five years.

Reverse. The principal series confined to B2 shoulders is from Walch's group: 27 reverses in patients with a mean age of 74 years, mean preoperative retroversion of 32 degrees, and mean humeroscapular alignment of 87%. At a mean of 54 months the Constant score had improved from 31 to 76. Four patients (15%) had complications, one an early glenoid loosening and three neurologic; 37% had scapular notching; posterior instability did not recur [46]. The rest of the reverse evidence for this problem comes from comparisons with the anatomic total shoulder [39, 42]; in the two systematic reviews, the reverse patients were older than the anatomic patients by nine years and by four [30, 36].

Three things can be said. In every one of these series, the improvement the operation produced was several times the minimal clinically important difference. In the ream-and-run and noncorrective anatomic series, being a B2 did not predict a worse result. And the differences reported between operations are small next to the difference each operation makes.

One thing cannot be said: which of the three is best for a particular patient with a B2 glenoid. Each operation's B2 results come from a different population. In the concurrent series, the ream-and-run patients averaged 58 years and were 92% male, and the total shoulder patients averaged 67 [5]; the reverse patients in the B2 literature averaged 72 to 74 [30, 36, 46].

A word about planning technology

The number these technologies aim at is not measured the same way from one study to the next. A systematic review of 61 studies (17,070 arthroplasties) relating preoperative glenoid version to an outcome found that only 27 (44%) described how version was measured. Of the 43 that measured postoperative version, 35% used a different imaging modality after surgery than before. Three-dimensional CT was used in 12.5% of studies published in 2012–2014 and in 52% of those published in 2021–2023 [9]. A target measured this inconsistently is difficult to relate to outcomes, and studies that use it are difficult to pool.

Three-dimensional CT is useful for knowing how much bone is present and where the vault is likely to be perforated. That is a different use from setting a version target. Planning software, custom guides, navigation, and robotic assistance add cost, radiation, and operative time in the service of reaching a number that has not been shown to predict how the patient will do [10, 11, 18]. In 8,117 arthroplasties in a large integrated health system, neither preoperative CT (hazard ratio 1.22, 95% confidence interval 0.87 to 1.72) nor patient-specific instrumentation (hazard ratio 1.44, 0.71 to 2.92) reduced the risk of aseptic revision. Mean follow-up was 2.9 years, which the authors note is short against a 5-year glenoid failure rate of 7.4% for the anatomic total shoulder in the Australian registry — the interval over which these technologies would show their value has not yet been observed [47].

An approach to the B2 shoulder

The goal of an anatomic arthroplasty, whether a ream-and-run or a total shoulder, is an articulation that moves freely and is stable. It is not to restore the premorbid anatomy of the glenoid or the humerus. Each step below serves that goal.

•      Assess the rotator cuff, the remaining glenoid bone stock, and the patient's age and activity.

•      Resect the humeral head at the anatomic neck and remove all osteophytes.

•      Limit the capsular release to the midsagittal plane so that posterior capsular support is preserved.

•      Take the glenoid ridge down with a burr, then ream minimally and concentrically to a single concavity preserving subchondral bone. Accept the residual retroversion. Reaming is sufficient when a round-backed trial does not tip under eccentric load.

•      If the patient desires an anatomic total shoulder, use a standard all-polyethylene component and seat it completely on well-prepared bone.

•      Select a humeral head thickness that allows no more than 50% posterior translation and no more than 60 degrees of internal rotation with the arm abducted. If excessive posterior decentering (the humeral head can be displaced substantially more than 50% of the width of the glenoid) is found when the trial components are in place, consider an anteriorly eccentric humeral head; add a rotator interval plication if that is not enough.

•      Reserve the reverse for rotator cuff deficiency, for bone that will not support a glenoid component, and for some older, lower-demand patients.

Where we are

The B2 glenoid is commonly found in shoulder arthritis. Patients with B2 glenoids vary widely: by age, sex, activity expectations, cuff integrity, range of motion, preoperative pathoanatomy (version, decentering, severity of biconcavity), bone quality and intraoperative findings. We can offer these patients a number of different procedures, including ream-and-run, pyrocarbon hemiarthroplasty, anatomic total shoulder (with or without corrective reaming and with or without augmented glenoid components), and reverse total shoulder.

The task for the surgeon is to match each patient with the procedure most likely to durably improve their comfort and function.



One thing for sure

This is a bee


The author has no financial relationships with any orthopaedic device company.

Follow on twitter/X: https://x.com/RickMatsen

Follow on facebook: https://www.facebook.com/shoulder.arthritis

Follow on LinkedIn: https://www.linkedin.com/in/rick-matsen-88b1a8133//

References

1. Walch G, Badet R, Boulahia A, Khoury A. Morphologic study of the glenoid in primary glenohumeral osteoarthritis. J Arthroplasty. 1999;14:756-760. doi:10.1016/S0883-5403(99)90232-2

2. Vo KV, Hackett DJ, Gee AO, Hsu JE. Classifications in brief: Walch classification of primary glenohumeral osteoarthritis. Clin Orthop Relat Res. 2017;475:2335-2340. doi:10.1007/s11999-017-5317-6

3. Schiffman C, Chin E, Whitson A, Hsu J, Matsen FA 3rd. Anatomic shoulder arthroplasty: a single surgeon’s consecutive series of four hundred and fifty eight patients. Int Orthop. 2026. doi:10.1007/s00264-026-07017-5

4. Collins AP, Sheth MM, Stenson JF, Kahsai EA, Khoo KJ, Ogunleye T, Whitson AJ, Matsen FA 3rd, Hsu JE. Characterizing glenoid wear after hemiarthroplasty with concentric glenoid reaming: a study of 113 arthroplasties at a mean of 6.7 years of follow-up. J Shoulder Elbow Surg. 2026;35:995-1002. doi:10.1016/j.jse.2025.08.014

5. Matsen FA 3rd, Whitson A, Jackins SE, et al. Ream and run and total shoulder: patient and shoulder characteristics in five hundred forty-four concurrent cases. Int Orthop. 2019;43:2105-2115. doi:10.1007/s00264-019-04352-8

6. Matsen FA 3rd, Gupta A. Axillary view: arthritic glenohumeral anatomy and changes after ream and run. Clin Orthop Relat Res. 2014;472:894-902. doi:10.1007/s11999-013-3327-6

7. von Eisenhart-Rothe R, Müller-Gerbl M, Wiedemann E, Englmeier KH, Graichen H. Functional malcentering of the humeral head and asymmetric long-term stress on the glenoid: potential reasons for glenoid loosening in total shoulder arthroplasty. J Shoulder Elbow Surg. 2008;17:695-702. doi:10.1016/j.jse.2008.02.008

8. Nyffeler RW, Jost B, Pfirrmann CW, Gerber C. Measurement of glenoid version: conventional radiographs versus computed tomography scans. J Shoulder Elbow Surg. 2003;12:493-496. doi:10.1016/S1058-2746(03)00181-2

9. Varady NH, Bram JT, Chow J, Taylor SA, Dines JS, Fu MC, Ode G, Dines DM, Gulotta LV, Brusalis C. Inconsistencies in measuring glenoid version in shoulder arthroplasty: a systematic review. J Shoulder Elbow Surg. 2025;34:639-649. doi:10.1016/j.jse.2024.08.020

10. Service BC, Hsu JE, Somerson JS, Russ SM, Matsen FA 3rd. Does postoperative glenoid retroversion affect the 2-year clinical and radiographic outcomes for total shoulder arthroplasty? Clin Orthop Relat Res. 2017;475:2726-2739. doi:10.1007/s11999-017-5433-3

11. Sheth MM, Mills ZD, Dasari SP, Whitson AJ, Matsen FA 3rd, Hsu JE. Anatomic total shoulder arthroplasty for posteriorly eccentric and concentric osteoarthritis: a comparison at a minimum 5-year follow-up. J Shoulder Elbow Surg. 2025;34:473-483. doi:10.1016/j.jse.2024.04.026

12. Hsu JE, Gee AO, Lucas RM, Somerson JS, Warme WJ, Matsen FA 3rd. Management of intraoperative posterior decentering in shoulder arthroplasty using anteriorly eccentric humeral head components. J Shoulder Elbow Surg. 2016;25:1980-1988. doi:10.1016/j.jse.2016.02.027

13. Matsen FA 3rd, Whitson AJ, Somerson JS, Hsu JE. Anatomic total shoulder arthroplasty with all-polyethylene glenoid component for primary osteoarthritis with glenoid deficiencies. JB JS Open Access. 2020;5(4):e20.00002. doi:10.2106/JBJS.OA.20.00002

14. Matsen FA 3rd, Warme WJ, Jackins SE. Can the ream and run procedure improve glenohumeral relationships and function for shoulders with the arthritic triad? Clin Orthop Relat Res. 2015;473:2088-2096. doi:10.1007/s11999-014-4095-7

15. Garrigues GE, Quigley RJ, Johnston PS, Spencer E, Walch G, Neyton L, Kelly J, Schrumpf M, Gillespie R, Sears BW, Hatzidakis AM, Lau B; PerFORM Investigators. Early clinical and radiographic outcomes of anatomic total shoulder arthroplasty with a biconvex posterior augmented glenoid for patients with posterior glenoid erosion: minimum 2-year follow-up. J Shoulder Elbow Surg. 2022;31:1729-1737. doi:10.1016/j.jse.2021.12.047

16. Cogan CJ, Patel M, Guevara J, Sahoo S, Jun BJ, Zhang C, Shemo C, Baker A, Qi A, Entezari V, Iannotti JP, Ho JC, Ricchetti ET. Short-term outcomes of anatomic total shoulder arthroplasty with nonaugmented glenoid component for Walch B2 and B3 glenoid morphology. J Shoulder Elbow Surg. 2025;34:S10-S21. doi:10.1016/j.jse.2025.01.023

17. Walch G, Moraga C, Young A, Castellanos-Rosas J. Results of anatomic nonconstrained prosthesis in primary osteoarthritis with biconcave glenoid. J Shoulder Elbow Surg. 2012;21:1526-1533. doi:10.1016/j.jse.2011.11.030

18. Checketts JX, Sanchez B, Norris G, Williamson TK, Hachadorian ME, Hsu JE, Schiffman CJ, Matsen FA 3rd. Does postoperative glenoid component retroversion following anatomic total shoulder arthroplasty affect clinical outcomes? A systematic review and meta-analysis. J Shoulder Elbow Surg. 2026;35:1103-1116. doi:10.1016/j.jse.2025.08.011

19. Rutledge JC, Dey Hazra RO, Geissbuhler AR, Yamaura K, Dey Hazra ME, Hanson JA, Rupp MC, Millett PJ. Does glenoid version and its correction affect outcomes in anatomic shoulder arthroplasty? A systematic review. J Shoulder Elbow Surg. 2024;33:e384-e399. doi:10.1016/j.jse.2023.10.031

20. Harold RE, Sweeney PT, Torchia MT, Chamberlain AM, Keener JD. Total shoulder arthroplasty in patients with a B2 glenoid addressed with corrective reaming: mean 8-year follow-up. J Shoulder Elbow Surg. 2023;32:S8-S16. doi:10.1016/j.jse.2022.12.019

21. Simovitch R, Flurin PH, Wright T, Zuckerman JD, Roche CP. Quantifying success after total shoulder arthroplasty: the minimal clinically important difference. J Shoulder Elbow Surg. 2018;27:298-305. doi:10.1016/j.jse.2017.09.013

22. Tashjian RZ, Hung M, Keener JD, Bowen RC, McAllister J, Chen W, Ebersole G, Granger EK, Chamberlain AM. Determining the minimal clinically important difference for the American Shoulder and Elbow Surgeons score, Simple Shoulder Test, and visual analog scale (VAS) measuring pain after shoulder arthroplasty. J Shoulder Elbow Surg. 2017;26:144-148. doi:10.1016/j.jse.2016.06.007

23. Pearl ML. CORR Insights®: Does postoperative glenoid retroversion affect the 2-year clinical and radiographic outcomes for total shoulder arthroplasty? Clin Orthop Relat Res. 2017;475:2740-2743. doi:10.1007/s11999-017-5457-8

24. Whong Z, Chow AK, Whitaker S, Smith MS, Cuthbert AS, Setliff J, Cyrus J, Vanderbeck J, Satalich J. Outcomes of anatomic total shoulder arthroplasty in B2 versus B3 glenoid morphology: a systematic review. J Orthop. 2026;76:230-238. doi:10.1016/j.jor.2026.04.003

25. Chamberlain AM, Orvets N, Patterson B, Chalmers P, Gosselin M, Salazar D, Keener JD. Total shoulder arthroplasty with an anterior-offset humeral head in patients with a B2 glenoid. JSES Int. 2020;4:638-643. doi:10.1016/j.jseint.2020.02.001

26. Cirino CM, Kantrowitz DE, Boucher T, Patel A, Duey AH, Cagle PJ, Flatow EL. Anatomic total shoulder arthroplasty for B2 glenoids treated with asymmetric reaming has equivalent survivorship and patient outcomes compared with type A glenoids at a mean 9-year follow-up. J Shoulder Elbow Surg. 2024;33:2392-2399. doi:10.1016/j.jse.2024.03.030

27. Hinse S, Pastor T, Hasler A, Ernstbrunner L, Wieser K, Gerber C. Mid- to long-term clinical and radiological results of anatomic total shoulder arthroplasty in patients with B2 glenoids. JSES Int. 2023;7:464-471. doi:10.1016/j.jseint.2023.01.006

28. Chen X, Reddy AS, Kontaxis A, Choi DS, Wright T, Dines DM, et al. Version correction via eccentric reaming compromises remaining bone quality in B2 glenoids: a computational study. Clin Orthop Relat Res. 2017;475:3090-3099. doi:10.1007/s11999-017-5510-7

29. Aleem AW, Orvets ND, Patterson BC, Chamberlain AM, Keener JD. Risk of perforation is high during corrective reaming of retroverted glenoids: a computer simulation study. Clin Orthop Relat Res. 2018;476:1612-1619. doi:10.1007/s11999.0000000000000302

30. Reahl GB, Abdul-Rassoul H, Kim RL, Ardavanis KS, Novikov D, Curry EJ, Galvin JW, Eichinger JK, Li X. Anatomic vs. reverse shoulder arthroplasty for the treatment of Walch B2 glenoid morphology: a systematic review and meta-analysis. JSES Rev Rep Tech. 2021;1:317-328. doi:10.1016/j.xrrt.2021.08.003

31. Hollo D, Raniga S, Cadosch D, Müller AM, Bokor DJ. Improved surgical techniques and outcomes with anatomic total shoulder arthroplasty managing B2 glenoids in midterm follow-up. Obere Extremität. 2024;19:44-53. doi:10.1007/s11678-023-00780-6

32. Luedke C, Kissenberth MJ, Tolan SJ, Hawkins RJ, Tokish JM. Outcomes of anatomic total shoulder arthroplasty with B2 glenoids: a systematic review. JBJS Rev. 2018;6(4):e7. doi:10.2106/JBJS.RVW.17.00112

33. Ho JC, Amini MH, Entezari V, Jun BJ, Alolabi B, Ricchetti ET, Iannotti JP. Clinical and radiographic outcomes of a posteriorly augmented glenoid component in anatomic total shoulder arthroplasty for primary osteoarthritis with posterior glenoid bone loss. J Bone Joint Surg Am. 2018;100:1934-1948. doi:10.2106/JBJS.17.01282

34. Kohan EM, Hendy BA, Kowal LL, Kirsch J, Gregori P, Williams GR, Namdari S. Mid- to long-term outcomes of augmented and nonaugmented anatomic shoulder arthroplasty in Walch B3 glenoids. J Shoulder Elbow Surg. 2022;31:S103-S109. doi:10.1016/j.jse.2021.12.016

35. Goetti P, Lannes X, Becce F, Farron A, Hoffmann L, Terrier A. Five-year outcomes of anatomic total shoulder arthroplasty with Aequalis Perform+ posterior augmented glenoid implants in Walch B2 and B3 glenoids. J Shoulder Elbow Surg. 2026;35:e13-e21. doi:10.1016/j.jse.2025.04.001

36. Aleisawi H, Kruse C, Nucci N, Alturki N, Abdel Khalik H, Athwal GS, Khan M. Outcomes of anatomic versus reverse shoulder arthroplasty for B2 and B3 glenoids with an intact rotator cuff: an updated systematic review and proportional meta-analysis. Shoulder Elbow. 2026;18(3). Published online July 17, 2025. doi:10.1177/17585732251359590

37. Priddy M, Zarezadeh A, Farmer KW, Struk AM, King JJ 3rd, Wright TW, Schoch BS. Early results of augmented anatomic glenoid components. J Shoulder Elbow Surg. 2019;28:S138-S145. doi:10.1016/j.jse.2019.04.014

38. Iannotti JP, Jun BJ, Derwin KA, Ricchetti ET. Stepped augmented glenoid component in anatomic total shoulder arthroplasty for B2 and B3 glenoid pathology: a study of early outcomes. J Bone Joint Surg Am. 2021;103:1798-1806. doi:10.2106/JBJS.20.01420

39. Cuff DJ, Simon P, Patel JS, Munassi SD. Anatomic shoulder arthroplasty with high side reaming versus reverse shoulder arthroplasty for eccentric glenoid wear patterns with an intact rotator cuff: comparing early versus midterm outcomes with minimum 7 years of follow-up. J Shoulder Elbow Surg. 2023;32:972-979. doi:10.1016/j.jse.2022.10.017

40. Simovitch R, Flurin PH, Wright T, Zuckerman JD, Roche CP. Quantifying success after total shoulder arthroplasty: the substantial clinical benefit. J Shoulder Elbow Surg. 2018;27:903-911. doi:10.1016/j.jse.2017.12.014

41. McLaughlin RJ, Whitson AJ, Panebianco A, Warme WJ, Matsen FA 3rd, Hsu JE. The minimal clinically important differences of the Simple Shoulder Test are different for different arthroplasty types. J Shoulder Elbow Surg. 2022;31:1640-1646. doi:10.1016/j.jse.2022.02.010

42. Polisetty TS, Swanson DP, Hart PJ, Cannon DJ, Glass EA, Jawa A, Levy JC, Kirsch JM. Anatomic and reverse shoulder arthroplasty for management of type B2 and B3 glenoids: a matched-cohort analysis. J Shoulder Elbow Surg. 2023;32:1629-1637. doi:10.1016/j.jse.2023.02.125

43. Sharareh B, Whitson AJ, Matsen FA 3rd, Hsu JE. Minimum 10-year follow-up of anatomic total shoulder arthroplasty and ream-and-run arthroplasty for primary glenohumeral osteoarthritis. J Shoulder Elbow Surg. 2024;33:1276-1284. doi:10.1016/j.jse.2023.08.028

44. Stenson JF, Collins AP, Yao JJ, Sharareh B, Whitson AJ, Matsen FA 3rd, Hsu JE. Factors associated with success of ream-and-run arthroplasty at a minimum of 5 years. J Shoulder Elbow Surg. 2023;32:S85-S91. doi:10.1016/j.jse.2023.01.024

45. Grantham WJ, Dekker TJ, Lacheta L, Horan MP, Goldenberg BT, Elrick BP, Millett PJ. Total shoulder arthroplasty outcomes after noncorrective, concentric reaming of B2 glenoids. JSES Int. 2020;4:644-648. doi:10.1016/j.jseint.2020.04.006

46. Mizuno N, Denard PJ, Raiss P, Walch G. Reverse total shoulder arthroplasty for primary glenohumeral osteoarthritis in patients with a biconcave glenoid. J Bone Joint Surg Am. 2013;95:1297-1304.

47. Navarro RA, Chan PH, Prentice HA, Pearl M, Matsen FA 3rd, McElvany MD. Use of preoperative CT scans and patient-specific instrumentation may not improve short-term adverse events after shoulder arthroplasty: results from a large integrated health-care system. JB JS Open Access. 2023;8:e22.00139. doi:10.2106/JBJS.OA.22.00139