Reverse total shoulder: what is the ideal humeral stem?

In contrast to the situation in an anatomic shoulder arthroplasty (below left), the center of rotation (center of yellow circle) in a reverse total shoulder (below right) is not closely aligned with the humeral medullary canal (red line). This results in a rotational moment arm (blue line) and a bending force each of which can contribute to loosening of the humeral stem in the humeral canal.



These loosening factors need be resisted by secure and durable fixation of the prosthesis to bone.

Recently there has been interest in short stemmed reverse humeral components.

However the short stem places the implant at risk for shift in component position as shown below.


Some have tried to manage this tendency for loosening by using tight fitting components, but these can increase the risk of stress shielding as shown below.



And can be difficult to revise in case of malposition, infection or fracture.


I found this recent article co-authored by Patrick Denard of relevance: Volumetric Humeral Canal Fill Ratio Effects Primary Stability and Cortical Bone Loading in Short and Standard Stem Reverse Shoulder Arthroplasty: A Biomechanical and Computational Study. 

The authors used cadaveric specimens to evaluate the effect of three-dimensional volumetric humeral canal fill ratios of reverse shoulder arthroplasty short and standard stems on the biomechanical stability and bone deformations in the proximal humerus. 

They compared standard stems inserted with low and high filling ratios and short stems inserted with low and high filling ratios. 


The specimens were cyclically loaded while optical recording allowed for spatial implant tracking and the quantification of cortical bone deformations in the proximal humerus. 

Both short and standard-length stem RSA humeral components implanted with a low canal filling ratio maintain dynamic bone loading in the medial calcar of the humerus similar to the native bone tested. This dynamic bone loading is desirable in the prevention of bone losss from stress shielding. Thus high canal fill ratios ( > 0.72) may correlate with the severity of bone resorption in the clinical setting.

However, short stems implanted with a low filling ratio (< 0.72) have an increased risk for implant tilt and subsidence compared to those inserted with high filling ratios or standard length stems. Short stems inserted with higher filling ratios and standard length stems implanted with low or high filling ratios demonstrated higher primary stability.

 
A conclusion from the foregoing is that short stems are at risk for stress shielding if they are inserted with high filling ratios, and at risk for loosening (tilt and subsidence) if they are inserted with low filling ratios. 

So, one can reduce the risks of stress shielding and component loosening through the use of a standard length smooth stem inserted with a low filling ratio as seen in the x-ray below with a stable humeral component and no bone resorption two years after reverse total shoulder arthroplasty. Secure fixation is achieved through impaction autografting.

You can support cutting edge shoulder research that is leading to better care for patients with shoulder problems, click on this link

Follow on twitter/X: https://x.com/RickMatsen

Here are some videos that are of shoulder interest
Shoulder arthritis - what you need to know (see this link).
How to x-ray the shoulder (see this link).
The ream and run procedure (see this link).
The total shoulder arthroplasty (see this link).
The cuff tear arthropathy arthroplasty (see this link).
The reverse total shoulder arthroplasty (see this link).
The smooth and move procedure for irreparable rotator cuff tears (see this link)
Shoulder rehabilitation exercises (see this link). 












Saturday, April 25, 2020

Reverse total shoulder - humeral stress shielding

Short-term evaluation of humeral stress shielding following reverse shoulder arthroplasty using press-fit fixation compared with cemented fixation

These authors compared the functional outcomes and humeral stress shielding of a reverse shoulder arthroplasty (RSA) placed with either cement or press-fit fixation. The stems were identical in geometry and coating with the only variable being whether the stems were secured with cement or by a press-fit technique. 


At minimum of two year followup, they found no significant differences in ranges of motion or functional outcomes between the two groups. 

Proximal lateral stress shielding was more common in the press-fit group (68%) than in the cemented group (25%). 



The authors concluded that at short-term follow-up, there were no differences in functional outcomes or stem loosening between press-fit fixation and cemented fixation of an RSA humeral stem. Proximal stress shielding was more common with press-fit fixation with the stem in this study, but the overall changes were considered low in 97% of cases. They pointed out that further study is needed to evaluate the mid- to long-term differences regarding stress shielding.

Comment: Humeral stress shielding results when the humeral prosthesis applies loads localized to some areas of the bone with unloading of other areas, resulting in bone resorption. It seems likely that cement helps even out the load distribution from prosthesis to bone.

Another way to even out the load distribution is to select a stem without a large metaphysical flare and of a size that is too small for a secure press fit in the patient's humerus (i.e. providing a small filling ratio).
The implant is then secured with impaction autografting or allografting to spread the load from the humeral component to the humerus


This approach can minimize stress shielding

by reducing the filling ratio (the ratio of the implant width (red line) to the humerus width (blue line))




This approach also has the advantages of bone preservation and of facilitating revision, should it become necessary.

===
To see a YouTube of our technique for a reverse total shoulder arthroplasty, click on this link.
===
How you can support research in shoulder surgery Click on this link.

We have a new set of shoulder youtubes about the shoulder, check them out at this link.

Be sure to visit "Ream and Run - the state of the art" regarding this radically conservative approach to shoulder arthritis at this link and this link

Use the "Search" box to the right to find other topics of interest to you.

You may be interested in some of our most visited web pages  arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'

Monday, July 29, 2019

Total shoulder arthroplasty - humeral stem fixation and calcar resorption

Medial calcar bone resorption after anatomic total shoulder arthroplasty: does it affect outcomes?

These authors sought to determine whether humeral bone resorption was associated with inferior outcomes or higher rates of radiographic loosening in 171 TSA patients with average clinical and radiographic followup periods of 50 and 46 months, respectively.

A press-fit technique was used for humeral stem insertion in all cases. Humeral stem size was based on the first sequential broach that obtained rotational stability, typically achieving metaphyseal fixation rather than diaphyseal fixation. Morsalized bone graft from the humeral head was placed into the prepared humeral canal shortly before impaction of the final stem. The glenoid was prepared using standard noncannulated reamers, creating a concentrically matched surface for the glenoid component, often partially correcting glenoid version. The glenoid component was cemented in all cases, with pressurization of cement into the prepared glenoid surface and placement of cement behind the component prior to impaction.

Calcar resorption was identified in 110 patients (64.3%).



No significant overall differences were observed between the patient characteristics or outcomes with and without calcar resorption.

Subgroup analysis showed that patients with grade 3 resorption had a higher incidence of glenoid radiolucencies (50%, P ..001) and patients with a progression from grade 1 to grade 3 had higher incidences of glenoid (50%, P . .003) radiolucencies.




3 months post op
 88 months post op


Comment: These authors point out that other risk factors for calcar osteolysis may be more important that stress-shielding.  For example, third body wear related to polyethylene and/or cement debris contributes directly to debris-induced osteolysis. The cement technique used in this series included placement of cement onto the backside of the glenoid component. While this has been shown to improve initial glenoid fixation, the thin cement mantles that results could have led to cracks in the cement and resulting wear particles. Patients with quick progression to grade 3 were found to have significantly greater glenoid and humeral radiolucent lines. They also mention that postoperative infection may also result in both medial calcar resorption and glenoid component loosening. 

They used a impaction autograft humeral fixation technique with low filling ratios to minimize the risk of stress-shielding.  Filling ratios assessed using the initial postoperative radiographs showed metaphyseal filling ratios pf  0.43±0.1 (maximum, 0.66; minimum, 0.21) while the filling ratio at the diaphyseal region was 0.41± 0.08 (maximum, 0.59; minimum, 0.22). These are lower than many studies and consistent with those in another recently described article that showed low levels of adaptive changes with a standard length impaction grafted stem (see below).

Radiographic outcomes of impaction-grafted standard-length humeral components in total shoulder and ream-and-run arthroplasty: is stress shielding an issue?

These authors evaluated humeral stress shielding after shoulder arthroplasty performed with a smooth, standard-length humeral stem fixed with impaction autografting.


Prior to placement of the final component, cancellous autograft harvested from the humeral head was placed in the humeral canal and pressed into place using a humeral impactor with the same stem geometry as the implant. Autograft was progressively inserted until the impactor fit tightly within the humerus. The final uncoated, smooth, stemmed, fixed-angle humeral component with the desired head geometry was then driven into the prepared canal. 
At two years after surgery, the radiographic appearances were evaluated by an independent experienced shoulder surgeon from another institution not involved in the care of these patients.  The metaphysical and diaphysial filling ratios were measured as shown below.



The filling ratios were small, showing a substantial preservation of bone stock.

The overall radiographic results are shown below

The 48 ream-and-run procedures showed partial calcar osteolysis in 9 cases (19%) and the 78 TSAs showed partial calcar osteolysis in 19 cases (24%) and complete calcar osteolysis in 2 (3%).

The Simple Shoulder Test score improved from 3.9±2.5 to 9.9±2.4.

Humeral component subsidence or component shift was observed in 3 ream-and-run procedures (6%) and in 8 TSAs (10%). These radiographic findings were not significantly associated with patient demographic characteristics, canal-filling ratios, or clinical outcomes.  






The authors concluded that this independent assessment of the 2-year radiographic and clinical outcomes of a conventional smooth humeral stem inserted with impaction autografting demonstrates the clinical utility of this bone-preserving approach to humeral component fixation with minimal complications; good clinical outcomes; and low rates of bone loss, component subsidence, and shift in position.

Comment: After three decades of use, impaction autografting of a smooth standard-length stem remains our preferred method for bone-preserving humeral component fixation.


Impaction allografting remains our preferred method for addressing failed prior humeral component fixation.



=====
We have a new set of shoulder youtubes about the shoulder, check them out at this link.

Be sure to visit "Ream and Run - the state of the art" regarding this radically conservative approach to shoulder arthritis at this link and this link

Use the "Search" box to the right to find other topics of interest to you.


You may be interested in some of our most visited web pages arthritis, total shoulder, ream and run, reverse total shoulder, CTA arthroplasty, and rotator cuff surgery as well as the 'ream and run essentials'